2021-03-18 12:02:53INTERIOR RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWINGS IN PROJECTDOX SHOULD BE ENTERED AS A SINGLE
 DRAWING NOT A PACKAGE OF DRAWINGS - THE ARCHITECTURAL
 DRAWINGS ARE ALL IN ONE FOLDER WHILE THE ELEC, PLUMBING
 AND MECHANICAL ARE ALL SEPARATED. SO WHEN THE
 ARCHITECTURAL "PACKAGE" WAS REVISED THERE ARE DRAWINGS
 MISSING BECAUSE YOU DID NOT PROVIDE A COMPLETE
 ARCHITECTURAL PACKAGE FOR THIS ROUND. THE FIRST ROUND
 "PACKAGE" FOR THE ARCHITECTURAL WERE VOIDED IN
 PROJECTDOX.
 2) PLEASE SHOW THE GRAB BAR LOCATIONS MORE SPECIFICALLY
 TO AVOID INCORRECT INSTALLATION FBC ACCESSIBILITY
 604.5.1SIDE WALL. 604.5.2REAR WALL.
 3) PLEASE SHOW THE TOILET PAPER DISTANCE FROM THE FACE
 OF THE TOILET TO THE CENTER OF THE DISPENSER TO AVOID
 INCORRECT INSTALLATION FBC 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.