| 2021-03-02 11:20:52 | PREVIOUS COMMENTS NOT ADDRESSED. |
| | |
| | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): |
| | 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED |
| | AND A GRAPHIC OF THE PROPOSED DOORS. |
| | 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE |
| | WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF |
| | AT [email protected] TO REQUEST THE EXAMPLE. AT |
| | MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND |
| | THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS |
| | GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION |
| | WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW |
| | MARKED. |
| | 3. A HORIZONTAL ROLLER IS INAPPROPRIATE WINDOW TYPE |
| | REPLACEMENT FOR SINGLE-HUNG/AWNING WINDOWS. REVISE TO |
| | SINGLE-HUNG OR PAIRED SINGLE-HUNG AS REQUIRED TO MATCH |
| | EXISTING. A 1-INCH, 2-INCH, OR 3-INCH MULLION MAY BE |
| | REQUIRED TO MATCH THE EXISTING MULLION WIDTH. |
| | 4. INDICATE COLOR OF EXTERIOR WINDOW FRAMES. ANODIZED |
| | OR WHITE. ANODIZED IS STRONGLY ENCOURAGED. |
| | 5. REVISE WINDOWS #2, #3, AND #4 TO MATCH THE EXISTING |
| | WINDOWS PORTIONS AND HAVE A MULLION TO MATCH. A 2-INCH |
| | WIDE MULLION MAY BE REQUIRED. THIS SERIES OF WINDOW CAN |
| | BE A CASEMENT-FIXED-CASEMENT (PREFERRED), |
| | FIXED-FIXED-FIXED, OR AN XOX HORIZONTAL ROLLER. A |
| | 4-LITE PATTERN WITH CGI SENTINEL?S LOW-PROFILE EXTERNAL |
| | MUNTIN WILL BE REQUIRED TO RECREATE THE APPEARANCE OF |
| | THE AWNING WINDOWS. |
| | 6. THE FRONT DOOR SIDELIGHTS INDICATED AS 1A AND 1B |
| | MUST HAVE A 6-LITE PATTERN TO REPLICATE THE EXISTING. |
| | PLEASE CONFIRM THE LOW PROFILE MUNTIN IS AVAILABLE FOR |
| | THIS SPECIFIC PRODUCT. |
| | 7. ALL SINGLE-HUNG WINDOWS WHEN REPLACING AN EXISTING |
| | 4-AWNING WINDOW SHALL HAVE A HORIZONTAL 2/2 LITE |
| | PATTERN WITH CGI?S LOW-PROFILE EXTERNAL MUNTIN. ALL |
| | CASEMENTS WHEN REPLACING AN EXISTING 2-AWNING WINDOW OR |
| | A SINGLE-HUNG SHALL HAVE A CENTER LOW-PROFILE EXTERNAL |
| | MUNTIN. PROVIDE REVISIONS AS NECESSARY. |
| | |
| | PROPOSED CONDITIONS, SUBJECT TO CHANGE: |
| | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE |
| | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND |
| | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL |
| | WINDOWS. |
| | 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED |
| | WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. |
| | 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. |
| | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR |
| | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS |
| | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. |
| | |
| | AARON BORNGRABER |
| | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES |
| | PLANNING DIVISION |
| | [email protected] | OFFICE: 561.822.1428 | TTY: |
| | 800.955.8771 |
| | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, |
| | FL 33402 |
| | |