Plan Review Notes
Plan Review Notes For Permit 20120587
Permit Number 20120587
Review Stop NFIP
Sequence Number 5
Notes
Date Text
2023-03-30 11:13:55ELEVATION CERTIFICATE REVIEW
 DENIED
  
 THESE REQUESTED CORRECTIONS HAVE NOT BEEN MADE. PLEASE
 MAKE THE FOLLOWING CORRECTIONS.
  
 SECTION A1. THE OWNERS NAME IS SHOULD BE RD IMV OWNER
 LLC
  
 SECTION A2. THE ADDRESS SHOULD BE 4328 N. FLAGLER DR.
  
 SECTION A4. THIS SHOULD STATE NON-RESIDENTIAL.
  
 SECTION C2 F). SPECIFY THE LOWEST ADJACENT GRADE NEXT
 TO THE BUILDING. (LAG)
  
 SECTION C2 G) SPECIFY THE HIGHEST ADJACENT GRADE NEXT
 TO THE BUILDING. (HAG)
  
 THE COMMENTS SECTION SHOULD SPECIFY THAT THE STRUCTURE
 IS BEING DRY FLOOD PROOFED UP TO THE DFE OF 9.0' NAVD
 88, SEE FLOOD PROOFING CERTIFICATE.
  
 THE FLOOD PROOFING CERTIFICATE AND OTHER DOCUMENTS ARE
 REQUIRED TO BE AT 9.0' NAVD 88 IN ORDER TO MEET THE
 CITY OF WEST PALM BEACHES MORE STRINGENT REQUIREMENT OF
 A 2' FREEBOARD ABOVE BFE.
  
  
  
  
  