| Date |
Text |
| 2021-04-05 09:14:25 | 3RD REVIEW FBC-2017 RES. |
| | PERMIT- 20120445 |
| | 4/5/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THE PRINTED NAME AND SIGNATURE OF KIRK ANGELOCCI |
| | (CFC024557) IS REQUIRED ON THE GAS RISER DRAWING AND |
| | COMBUSTION AIR CALCULATIONS- SECTION 107.2.1 WPB, AND |
| | FLORIDA STATUTES 471.003(2)(H) & 471.025. |
| | |
| | 2) 2ND REQUEST FOR A CONDENSATE DISPOSAL PLAN FOR THE |
| | WATER HEATER. PLEASE REVEW THE RINNAI INSTALL, MANUAL |
| | WHICH REQUIRES CONDENSATE DISPOSAL IN ACCDORDANCE WITH |
| | LOCAL CODES, AND ALSO RECOMMENDS INSTALLATION OF A |
| | NEUTRALIZER KIT TO PREVENT CORROSION OF THE CONDENSATE |
| | DRAIN AND THE PUBLIC SEWER SYSTEM- SECTION G2404.10 FBC |
| | RES. PLEASE NOTE THIS COMMENT WAS UNDER THE PLUMBING |
| | REVIEW AND NOT THE GAS. I HAVE RELOCATED IT FROM THE |
| | PLUMBING REVIEW- PLEASE COMPLY. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |