| Date |
Text |
| 2020-12-08 16:27:43 | ROOFING REVISION BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | 1- SELF-ADHERING MODIFIED BITUMEN ROOFING SYSTEM NOA |
| | 18-1219.01 SUBMITTED IS FOR CEMENTITIOUS WOOD FIBER |
| | DECKS. THIS TYPE OF ROOD DECKING DOESN'T SEEM TO MATCH |
| | ROOF DECK OF THIS STRUCTURE. ACCORDING TO CITY RECORDS |
| | THIS IS A WOOD FRAMED RESIDENTIAL STRUCTURE. TYPICALLY, |
| | THIS TYPE OF FRAMED BUILDINGS DON'T HAVE CEMENTITIOUS |
| | WOOD FIBER DECKS. MOST LIKELY, THERE IS A WOOD DECK IN |
| | THIS STRUCTURE. REVISE ROOFING NOA OR PROVIDE PROOF |
| | THAT THIS IS A CEMENTITIOUS WOOD FIBER DECK. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2- PROVIDE NEW ROOFING PRODUCT APPROVAL AND CLEARLY |
| | MARK WHICH APPROVED ASSEMBLY IS GOING TO BE INSTALLED |
| | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. NOTE: |
| | IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN |
| | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED |
| | RAS 117 CALCULATIONS ARE REQUIRED. SEE LIMITATIONS ON |
| | PRODUCT APPROVAL. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |