| Date |
Text |
| 2020-12-30 08:52:19 | PLAN REVIEW / BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2014 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. PROVIDE PROJECT DATA/DESIGN PARAMETERS: |
| | |
| | PROJECT DATA: 1&2 FAMILY DWELLING UNIT |
| | OCCUPANCY CLASSIFICATION R3 SFR |
| | SCOPE OF WORK |
| | |
| | |
| | DESIGN PARAMETERS: 2017 FBC EXISTING BUILDING |
| | 2017 FBC RESIDENTIAL |
| | 2014 NEC |
| | |
| | CLASSIFICATION OF WORK: ALTERATION LEVEL II |
| | BUILDING CLASSIFICATION: VB |
| | EXPOSURE CLASSIFICATION: C |
| | RISK CATEGORY: II |
| | MEAN ROOF HEIGHT: |
| | |
| | SITE SPECIFIC DESIGN WIND LOADS PER: |
| | ASCE 7-10(VULT 170MPH 3 SEC GUST / VASD 132MPH) |
| | 2017 FBC R CHPT. 3 |
| | |
| | DESIGN WIND PRESSURES: |
| | WINDOWS AND DOORS ZONE 4 INT. / ZONE 5 CORNER |
| | (POSITVE/NEGATIVE) |
| | ROOF ZONE 1 (FIELD), ZONE 2 (EDGE), ZONE 3 (CORNERS) |
| | R301.2.1 WIND DESIGN CRITERIA. |
| | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN |
| | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING |
| | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED |
| | FROM FIGURE R301.2(4). |
| | |
| | 2. PROVIDE DOOR AND WINDOW SCHEDULE: INCLUDE ROUGH |
| | OPENING AND DESIGN PRESSURES. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | R301.2.1 WIND DESIGN CRITERIA. |
| | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN |
| | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING |
| | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED |
| | FROM FIGURE R301.2(4). |
| | |
| | 3. PROVIDE PRODUCT APPROVALS FOR NEW AND RELOCATED |
| | WINDOWS AND EXT. DOORS AND LINTELS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE WINDOW, DOOR AND LINTEL |
| | SUBMITTALS. |
| | 104.9.1 USED MATERIALS AND EQUIPMENT. THE USE OF USED, |
| | RECYCLED, OR RECLAIMED MATERIALS WHICH MEET THE |
| | REQUIREMENTS OF THIS CODE FOR NEW MATERIALS IS |
| | PERMITTED. USED EQUIPMENT AND DEVICES SHALL NOT BE |
| | REUSED UNLESS APPROVED BY THE BUILDING OFFICIAL. |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | 4. PROVIDE DETAIL OF EXTERIOR WALL IN-FILL AND INTERIOR |
| | BLOCK WALL IN-FILL. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |
| | |
| | |