| 2020-12-18 15:41:32 | FENCE/GATE SHOP DRAWINGS |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected]. |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) SHOP DRAWINGS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE BUILDING DESIGNER OF RECORD. FBC WPB |
| | 107.3.4.1 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL |
| | BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED |
| | AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF |
| | THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE |
| | INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN |
| | APPROVED BY THE BUILDING OFFICIAL. |
| | 2) PLEASE PROVIDE A SITE PLAN/FLOOR PLAN SHOWING THAT |
| | THE GATE COMPLIES WITH FBC 454.1.3.1.9 |
| | ALL PUBLIC POOLS SHALL BE SURROUNDED BY A MINIMUM 48 |
| | INCH (1219 MM) HIGH FENCE OR OTHER APPROVED SUBSTANTIAL |
| | BARRIER. THE FENCE SHALL BE CONTINUOUS AROUND THE |
| | PERIMETER OF THE POOL AREA THAT IS NOT OTHERWISE |
| | BLOCKED OR OBSTRUCTED BY ADJACENT BUILDINGS OR |
| | STRUCTURES AND SHALL ADJOIN WITH ITSELF OR ABUT TO THE |
| | ADJACENT MEMBERS. ACCESS THROUGH THE BARRIER OR FENCE |
| | FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL |
| | ROOMS AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING, |
| | SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM) |
| | MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH |
| | LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE |
| | BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW |
| | THE TOP OF THE GATE ON THE POOL SIDE. IF THE |
| | SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING |
| | AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR |
| | INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF |
| | SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 |
| | MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED |
| | FLOOR OR GROUND. |