| 2021-05-28 07:46:43 | THE DESIGNER OF THE MECHANICAL EQUIPMENT SIZING |
| | CALCULATIONS AND THE MECHANICAL DRAWING MUST HAVE THEIR |
| | NAME AND SIGNATURE ON THE DRAWINGS AND SIZING |
| | CALCULATIONS. THE DESIGNER MUST BE EITHER AN ENGINEER |
| | OR THE MECHANICAL CONTRACTOR HOLDING THE PERMIT TO |
| | INSTALL THIS EQUIPMENT AT THIS LOCATION. |
| | |
| | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN |
| | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE |
| | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE |
| | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE |
| | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE |
| | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET |
| | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL |
| | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |
| | [email protected] |
| | |
| 2021-05-28 07:36:56 | 2ND REVIEW FBC-2020 MECHANICAL |
| | PERMIT-20110999 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC B- FLORIDA BUILDING CODE |
| | FBC M- FLORIDA MECHANICAL CODE |
| | FBC EC- FLORIDA ENERGY CONSERVATION |
| | FBC FG- FLORIDA FUEL GAS |
| | FBC EX- FLORIDA EXISTING BUILDING CODE |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING |
| | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN |
| | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE |
| | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE |
| | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. |
| | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A |
| | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING |
| | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, |
| | OR |
| | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL |
| | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE |
| | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER |
| | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO |
| | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. |
| | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| | OF THE PERSON RESPONSIBLE FOR THE DESIGN. |
| | |
| | 2) EACH STRUCTURE MUST HAVE A SEPARATE PERMIT. FBC M |
| | 107.2.1 |
| | |
| | 3) PLEASE IDENTIFY ALL DOCUMENTS TO CLEARLY SHOW WHICH |
| | STRUCTURE THE DOCUMENT IS ASSOCIATED WITH. FBC 107.2.1 |
| | |
| | 4) PLEASE SHOW THE CONDENSATE DRAIN PIPING AND LOCATION |
| | OF CONDENSATE DISPOSAL. FBC RES M1411.3 |
| | |
| | 5) PLEASE SHOW THE ANCHORING DETAILS FOR THE CONDENSING |
| | UNITS. FBC RES M1307.2 |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM. |
| | |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |