| Plan Review Notes For Permit 20110548 |
| Permit Number |
20110548 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2020-12-03 16:41:30 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SCHEDULE OF OPENING PROTECTIVE DEVICES OR | | | ASSEMBLIES. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. SHUTTER SCHEDUEL SUBMITTED IS MISSING THE FOLLWING | | | INFORMATION: | | | 2A) SHUTTER MOUNTING CONNECTION TYPE | | | 2B) SHUTTER GLASS SEPERATION | | | 2C) SHUTTER SPAN | | | 2D) SHUTTER ORIENTATION - V/H | | | 2E) EDGE DISTANCE | | | 2F) ANCHOR SPACING | | | 2G) SUBSTRATE | | | 2H) CENTER BOLTS REQUIRED - Y/N | | | | | | YOU MAY OBTAIN A COPY OF THE CITY'S SHUTTER SCHEDULE | | | UPON REQUEST. SEE E-MAIL ABOVE. |
|