| Date |
Text |
| 2020-11-24 08:47:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20110536 |
| | ADD: 106 N. OLIVE AVE. |
| | CONT: TRIBECA INVESTMENTS INC |
| | TEL: 561-239-0750 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. NOV. 24TH/ 2020 |
| | ACTION: DENIED |
| | |
| | 1) PROVIDE A SURVEY AND SHOW ON THE SURVEY WHERE THIS |
| | CONSTRUCTION WILL OCCUR. 107.3.5 MINIMUM PLAN REVIEW |
| | CRITERIA. |
| | |
| | 2) UNDER THE HEADING SCOPE OF WORK THE PLAN S-1 DOES |
| | NOT INDICATE TO THE CONSTRUCTION TYPE THIS BUILDING IS. |
| | PLEASE NOTE THE BUILDING CONSIST OF MANY ADDRESS. THE |
| | FURTHEST EAST PORTION OF THE BUILDING IS A 4 STORY |
| | BUILDING 1ST & 2ND FLOOR A-3 OCCUPANCY AND THE 3RD & |
| | 4TH FLOOR BUSINESS OCCUPANCY, THE BUILDING IS FULLY |
| | FIRE SPRINKLERED. PLEASE PROVIDE THE MINIMUM BUILDING |
| | TYPE. SHOW COMPLIANCE WITH THE 2017 FBC-B TABLE 504.4, |
| | & SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR |
| | SIDE OF EXTERIOR WALLS . |
| | |
| | 3) SHEET S-1 INDICATES THE ASCE 7-10 WIND DESIGN BUT IS |
| | STATING WIND PRESSURE TABLES OUT OF THE ONE & TWO |
| | FAMILY RESIDENTIAL CODE BOOK? PLEASE EXPLAIN WHY |
| | RESIDENTIAL TABLES? ASCE 7-10 USES FIGURE 30.5-1 FOR |
| | PRESSURES AND ADJUSTMENT FACTORS. |
| | |
| | 4) SHEET S-1 STATES THE USE OF FL 11560.1-R3PLEASE SHOW |
| | COMPLIANCE WITH THE 2017 FBC-B SECTIONS: |
| | |
| | 4A)COMPONENTS & CLADDING. 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, |
| | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ |
| | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(C) PANEL WALLS: STRAPS & HANGERS, BUCKETS |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | 4B)W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP |
| | DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD |
| | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC. |
| | |
| | 4C) 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, |
| | THE CONSTRUCTION DOCUMENTS SHALL IDENTIFY, ILLUSTRATE, |
| | DESCRIBE AND DELINEATE THE TYPE OF ROOFING SYSTEM, |
| | MATERIALS, VENTING, FASTENING REQUIREMENTS, FLASHING |
| | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE |
| | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND |
| | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND |
| | CRITERIA REQUIRED FOR THE SPECIFIC SITE. |
| | |
| | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |