2020-11-25 14:50:48STOREFRONT WINDOWS AND DOORS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 THESE COMMENTS ARE ONLY FOR THE REPLACEMENT OF THE
 STOREFRONT PER THE BUILDING PERMIT APPLICATION
 PROVIDED.
 1) BUILDING PERMIT APPLICATION SHOWS "WORK DESCRIPTION"
 AS "REPLACING STOREFRONTS" - THE PLANS PROVIDED FOR
 THIS PERMIT NUMBER SHOW STOREFRONTS, ROOFING, GUARD
 RAILINGS, INTERIOR SOFFITS ETC. PLEASE CLARIFY THE
 BUILDING PERMIT APPLICATION AND REMOVE DRAWINGS THAT DO
 NOT PERTAIN TO THIS PERMIT.
 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE STOREFRONT WINDOWS AND DOORS.
 (COMPLETE = FRONT PAGES AND THE INSTALLATION
 INSTRUCTIONS)
 3) PLEASE SHOW THE ANCHOR TYPE AND SIZE FOR THE
 INTERIOR SOFFIT FRAMING TO THE EXISTING STRUCTURE - ON
 DRAWING A-2
 4) THERE ARE MULTIPLE DRAWINGS OF (CS-1) (A-1) (A-2)
 (A-3) IN PROJECTDOX.
 5) DRAWINGS (S-1) AND (S-2) NEED TO BE SIGNED AND
 SEALED BY THE ENGINEER.
 6) PLEASE SHOW THAT DOOR THRESHOLDS, WIDTHS, OPENING
 AND CLOSING - COMPLY WITH ACCESSIBILITY REQUIREMENTS
 FBC ACCESSIBILITY 404
  
  