Plan Review Notes
Plan Review Notes For Permit 20110521
Permit Number 20110521
Review Stop E
Sequence Number 1
Notes
Date Text
2020-12-01 14:33:18CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: FAILED.
  
 1) PLEASE SHOW LOCATION OF NEW OUTSIDE PANEL AND
 IDENTIFY NEW ELECTRICAL PANEL A FBC 107
 2) GFCI, WP RECEPTACLE REQUIRED AT THE FRONT AND BACK
 OF THE DWELLING NEC 210.52(E)
 3) NOTE 1 MENTIONS ?GROUNDING CONDUCTORS REQUIRED AT
 SWITCH LOCATIONS PER NEC 404.2?. ARTICLE 404.2 OF NEC
 DOES NOT TALK ABOUT OR REFER TO GROUNDING CONDUCTORS
 REQUIRED AT SWITCH LOCATIONS.
 4) SPECIFY AVAILABLE FAULT CURRENT AT PANELS FBC 107
 5) EQUIPOTENTIAL POOL BONDING REQUIRED - NEC 680.26
 6) POOL RECEPTACLE REQUIRED - NEC 680-22
  
 PLEASE CLARIFY AND CORRECT.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.