| 2020-11-24 14:34:59 | NEW SFR |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected]. |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) PLEASE SHOW THE SILL HEIGHT FOR WINDOW MARK "J" TO |
| | COMPLY WITH EMERGENCY EGRESS REQUIREMENTS PER FBC |
| | R310.2.2 |
| | 2) DRAWING "S-3" IS THE WRONG DRAWING FOR THIS PROJECT. |
| | 3) PLEASE SHOW THE SETBACK DISTANCE FROM THE PROPERTY |
| | LINES FOR THE POOL PAVERS AND THE AC EQUIPMENT PADS. |
| | 4) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS. |
| | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE BUILDING DESIGNER OF RECORD. |
| | 5) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE |
| | ROOFING SYSTEM PRODUCT APPROVALS. IN THE PRODUCT |
| | APPROVAL PROVIDED FOR THE FLAT DECK - PLEASE CIRCLE THE |
| | ROOFING SYSTEM TO BE USED IN THE ROOFING PRODUCT |
| | APPROVAL - ROOFING SYSTEM TO BE USED ON THE PROVIDED |
| | PRODUCT APPROVAL MAY REQUIRE ADDITIONAL SIGNED AND |
| | SEALED ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER |
| | FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER |
| | PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL |
| | - SEE GENERAL LIMITATION NOTES ON THE PRODUCT APPROVAL. |
| | 6) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING |
| | THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE |
| | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY |
| | PROPOSED WATER RETAINING SWALES) |
| | 7) A SEPARATE DEMO PLAN IS REQUIRED - PLEASE SHOW |
| | PERMIT NUMBER FOR THE DEMO PERMIT. |
| | |