| Plan Review Notes For Permit 20110399 |
| Permit Number |
20110399 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2021-03-30 13:13:06 | DECK FOR A TEMPORARY MOBILE TRAILER | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE DOOR MANEUVERING CLEARANCE (IN AND | | | OUT OF THE EXISTING BUILDING) TO COMPLY WITH FBC | | | ACCESSIBILITY 404.2.4 - THE OUTSWING DOOR AT THE | | | BUILDING ENTRY NEEDS TO HAVE 18" CLEARANCE ON THE LATCH | | | SIDE FROM THE DOOR OPENING TO THE HANDRAIL. | | | 2) RAMP LANDINGS NEED TO BE A MINIMUM DIMENSION OF 5' X | | | 5' - PLEASE SHOW THE LANDING DIMENSIONS AT THE HIGHER | | | SIDE OF THE RAMP FBC 405.7.4 CHANGE IN DIRECTION. | | | RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS | | | SHALL HAVE A CLEAR LANDING 60 INCHES (1525 MM) MINIMUM | | | BY 60 INCHES (1525 MM) MINIMUM. | | | |
|