Plan Review Notes
Plan Review Notes For Permit 20110110
Permit Number 20110110
Review Stop B
Sequence Number 1
Notes
Date Text
2020-11-18 11:03:22PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
 A SEPERATE PERMIT IS REQUIRED FOR THE GUEST HOUSE.
 PRO-RATE THE VALUES AS FOLLOWS: MAIN HOUSE $531,076 AND
 GUEST HOUSE $93,924.
 SUBMIT THE GUEST HOUSE PERMIT APPLICATION TO -
 [email protected]
 PLANS FOR BOTH STRUCTURES WILL REMAIN UNDER 20110110 -
 MAIN HOUSE.
  
 1. PROVIDE A SITE PLAN. DRAINAGE/SURVEY
  
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
  
 FBC R401.3 SITE DRAINAGE
 PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 2. PROVIDE THE FINISHED FLOOR ELEVATION.
  
 FINISH FLOOR ELEVATION ? NON-FLOOD ZONE
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 3. PROVIDE A SOILS REPORT.
  
 GEOTECHNICAL INVESTIGATIONS
 FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL
 BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE
 REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL
 INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY
 TESTING OR ENGINEERING CALCULATIONS, SUCH
 INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED
 DESIGN PROFESSIONAL.
  
 4.NOTICE ONLY: PALM BEACH COUNTY IMPACT FEES REQUIRED.
 SEE COMMENTS UNDER IMPACT FEE REVIEW.
  
 5. STATE R VALUE OF 3/4" RIGID WALL INSULATION ON PLAN.
  
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 6. PROVIDE AN ENERGY SUBMITTAL.
  
 PROVIDE ENERGY GAUGE FORM R405 PER SECTION R405.2 FBC
 EC.
  
 7. PROVIDE WINDOW AND DOOR SCHEDULES WITH THE FOLLOWING
 INFORMATION:
 7A) WINDOW SCHEDULE -
 1. ITEM NUMBER
 2. LOCATION ON PLAN
 3. TYPE
 4. MFGR.
 5. MATERIAL
 6. GLASS TREATMENT
 7. ROUGH OPENING
 8. IMPACT RESISTANT Y/N
 9. PRODUCT APPROVAL NUMBER
 10. NOA DESIGN PRESSURE RATING
 11. OPENING REQUIRED PRESSURE RATING
 12. EGRESS REQUIRED Y/N
 13. SHUTTER REQUIRED Y/N
 7B) DOOR SCHEDULE
 1. ITEM NUMBER
 2. LOCATION ON PLAN
 3. SIZE
 4. THICKNESS
 5. TYPE
 6. MFGR.
 7. MATERIAL
 8. JAM
 9. ROUGH OPENING
 10. HARDWARE
 11. PRODUCT APPROVAL NUMBER
 12. NOA DESIGN PRESSURE RATING
 13. OPENING REQUIRED PRESSURE RATING
 14. SHUTTER REQUIRED Y/N
  
 8. DESINER SHALL SELECT MODEL OF SGD TO BE INSTALLED.
 NOTICE:
 OPENING PROTECTION REQUIRED IF N0N-IMPACT RATED DOOR
 SELECTED.
  
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 9. NOTICE ONLY: SUBMIT A ROOFING SUB-PERMIT AND
 REQUIRED PRODUCT APPROVALS OR A PROVISO WILL BE PLACED
 ON THE PLAN "SEPERATE ROOFING PERMIT REQUIRED.".
  
 PERMITS - 105.1 REQUIRED.
  
 PROVISO: PROVIDE ICC-ES REPORT FOR SPRAY FOAM
 INSULATION TO CITY INSPECTOR.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 ***THESE COMMENTS APPLY TO BOTH STRUCTURES AND WILL BE
 TRANSFERRED TO NEW GUEST HOUSE PERMIT***
  
 ***REDLINE ADDRESS PER SH***
  
  
  
  
  
  