| Date |
Text |
| 2020-11-10 16:51:09 | 1ST REVIEW FBC-2017 RES. FUEL GAS |
| | PERMIT- 20110051 |
| | 11/10/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) PROVIDE A SURVEY OR SITE PLAN DRAWING SHOWING THE |
| | LOCATIONS OF THE NEW GRILL AND FIREPIT, AND THE |
| | REQUIRED INSTALLATION CLEARANCES FROM PROPERTY LINES, |
| | COMBUSTIBLE CONSTRUCTION, AND AIR INTAKES AND OPENINGS |
| | INTO THE BUILDING- SECTION 107.2.1 WPB AND SECTION |
| | R303.5.1 FBC RES. |
| | |
| | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE GRILL |
| | AND FIREPIT HIGHLIGHTED OR MARKED UP TO SHOW THE ANSI |
| | STANDARD LISTINGS, AND THE BTUH LOADS AND INPUT |
| | PRESSURES- SECTION G2404.3 & G2408.1 FBC RES. |
| | |
| | 3) SUBMIT MARKED UP OR HIGHLIGHTED SPECS FOR THE |
| | REGULATORS SHOWING THE SELECTED MODELS, THE MAX INLET |
| | AND OUTLET SIZES AND PRESSURES, SPRING DATA, AND |
| | ORIFICE SIZES- SECTION G2421.1 & G2421.2 FBC RES. |
| | |
| | 4) PLEASE LIST THE PIPE SIZING TABLES ON THE RISER- |
| | SECTION G2413.3 FBC RES. |
| | |
| | 5) THE $1200.00 VALUE ON THE APPLICATION APPEARS TO BE |
| | LOW FOR THE SCOPE OF THE PROJECT. PLEASE PROVIDE A COPY |
| | OF A SIGNED CONTRACT AND/OR ESTIMATES AND INVOICES TO |
| | VERIFY THE COSTS OF LABOR, MATERIALS, EQUIPMENT, |
| | APPLIANCES, SITE WORK AND DESIGN FEES- SECTION 109.3 |
| | WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |