Plan Review Notes
Plan Review Notes For Permit 20101477
Permit Number 20101477
Review Stop B
Sequence Number 1
Notes
Date Text
2020-11-29 15:47:28WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20101477
 ADD: 2122 PALM BEACH LAKES BLVD./ SALVATION ARMY
 CONT: BARTLEY BUILDING GROUP
 TEL: 561-856-6494
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN. MOV. 29TH/2020
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION NEEDS TO HAVE A NOTARIZED
 SIGNATURE FOR THE CONTRACTOR OF RECORD BEFORE PERMIT
 ISSUANCE. 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE CODE
 SECTION 105.1 PERMITS.
  
 2) THE SUBMITTED PLANS BY JAIRO ROJAS, P. E. ARE NOT
 SIGNED NOR SEALED. WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATIVE CODE
 SECTION 107.1 SUBMITTAL DOCUMENTS/ SIGNATURES & SEALS.
 IF THE DESIGN PROFESSIONAL IS AN ARCHITECT, INTERIOR
 DESIGNER, LANDSCAPE ARCHITECT, OR ENGINEER LEGALLY
 REGISTERED UNDER THE LAWS OF THIS STATE REGULATING THE
 PRACTICE OF ARCHITECTURE OR INTERIOR DESIGN AS PROVIDED
 FOR IN CHAPTER 481, FLORIDA STATUTES, PART 1, OR
 LANDSCAPE ARCHITECT AS PROVIDED FOR IN CHAPTER 481,
 FLORIDA STATUTES, PART II, OR ENGINEERING AS PROVIDED
 FOR IN CHAPTER 471, FLORIDA STATUTES, THEN HE OR SHE
 SHALL AFFIX HIS OR HER OFFICIAL TO SAID DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA, AS REQUIRED BY
 FLORIDA STATUTES.
  
 3) THE COVERSHEET SHOWS THE SHAPE AND SQ. FEET OF
 BUILDING A. WHAT THE COVERSHEET NOR SHEET A1 SHOW IS
 THE AREA TO BE ALTERED IN RELATION TO THE INTERIOR OF
 BUILDING A. 107.2.1.2 ADDITIONAL INFORMATION IS
 REQUIRED TO DETERMINE CODE COMPLIANCE FOR THIS PROJECT.
  
 4) THE COVERSHEET LIST THIS BUILDING A TO HAVE 5010 SQ.
 FT. WHEREAS THE TENANT SPACE DATA HEADING LIST THE
 LEASE AREA AS 1,645 SF. THE NEW WOMEN?S MINISTRY ROOM
 ONLY SHOWS PROXIMATELY 320 SQ. FT.
  
 5) THE COVERSHEET BUILDING DESCRIPTION LIST THE CURRENT
 OCCUPANCY AS A BUSINESS OCCUPANCY AND THE PROPOSED
 OCCUPANCY AS A BUSINESS OCCUPANCY. SHEET A1 SHOWS THE
 ROOMS TO BE REMODELED TO BE STORAGE OCCUPANCY & THE
 PROPOSED REMODELED ROOMS TO BE A NEW WOMEN?S MINISTRY
 ROOM, OCCUPANT LOAD NOT GIVEN BUT PROBABLY LESS THAN 50
 MAKING THE PROPOSED NEW OCCUPANCY BUSINESS, A CHANGE IN
 OCCUPANCY, SEE THE 2017 EXESTING BUILDING CODE CHAPTER
 10 SECTION 1001.2.2.1 PARTIAL CHANGE OF OCCUPANCY.
  
 6) THE COVERSHEET UNDER THE HEADING OF BUILDING
 DESCRIPTION THE PLANS DO NOT STATE IF THE BUILDING IS
 FIRE SPRINKLERED OR NOT? AND IF IT IS WITH AN OCCUPANT
 LOAD OF 335 OCCUPANTS. WITH THE AREA BEING RENOVATED IS
 THAT INCLUDED IN THE 335 OCCUPANT LOAD COUNT. SEE 2017
 FBC-EXIST. BUILD. CODE 1012.1.1, 1012.1.1.1, 1012.1.1.2
 1012.2.2.1 AND SECTION 903.2.1.3 A-3 OCCUPANCIES.
  
 7) THE COVERSHEET EXIT ACCESS TRAVEL DISTANCE SHOWS THE
 COMMON PATH OF TRAVEL MAXIMUM OF 75 FEET, BUT SHEET A1
 SHOWS ONLY ONE COMMON PATH OF TRAVEL, AT A DISTANCE OF
 OVER 90 FEET. SHOW WHERE THERE ARE 2 MEANS OF EGRESS AS
 SHOWN THERE IS ONLY ONE. 2017 FBC-B TABLE 1006.2.1.
  
 8) SHEET A1 SHOWS 2 NEW DOOR OPENINGS. DOOR A AND DOOR
 B:
 8A) DOOR A DOES NOT HAVE THE REQUIRED 18 INCHES ON THE
 LATCH SIDE FOR MANEUVERING CLEARANCES. 2017 FBC-ACCESS.
 CODE 404.2.4 MANEUVERING CLEARANCES. DOORS. MINIMUM
 MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY
 WITH 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE
 FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE
 FOR SIDE CLEARANCE. SEE FIGURE 404.2.4.1(A).
  
 8B) PLEASE PROVIDE THE WIDTH OF THE CORRIDOR JUST
 OUTSIDE THE RESTROOM DOOR B TO SHOW COMPLIANCE WITH THE
 2017 FBC-ACCESSIBILITY CODE FIGURE 404.2.4.1(F).
  
 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved