| 2021-06-11 21:09:35 | COMMENTS FROM PREVIOUS LIST WERE NOT ADDRESSED. SEE |
| | BELOW. TO RECAP: |
| | CONTRACTORS NEED TO INCLUDE PRINTED NAME AND SIGNATURE |
| | ON EACH PAGE, LICENSE NUMBER |
| | FBC 109, VALUE TOO LOW, PROVIDE A COPY OF THE CONTRACT |
| | AND A COST BREAKDOWN |
| | SHOW SQUARE FOOT AREAS OF TILE TO BE INSTALLED. ON EACH |
| | PLAN INDICATE THE FLOORING TYPE THAT WILL BE INSTALLED. |
| | SCOPE IS NOT CLEAR, VALUE NOT CLEAR. |
| | [email protected], 561-805-6724 |
| | |
| | |
| | THESE ARE COMMENTS FROM PREVIOUS REVIEW WHICH ARE STILL |
| | NOT ADDRESSED |
| | |
| | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20101332 |
| | ADD: 1801 N. FLAGLER DR. # 501 |
| | CONT: COMPLETE CONSTRUCTION & DEVELOPMENT |
| | TEL: 561-687-8878 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: MON. MAY17TH/2021 |
| | ACTION: DENIED |
| | |
| | 1) 2ND REQUEST. THE ONLY PLANS SUBMITTED THIS TIME WITH |
| | THE QUALIFIER AND LICENSE NUMBER ON THE PLANS WAS |
| | ELECTRICAL, THERE WERE NO PLANS SUBMITTED WITH THE |
| | BUILDING CONTRACTOR QUALIFIER INFORMATION, NAME, |
| | PRINTED, SIGNATURE AND LICENSE NUMBER. |
| | 1ST ROUND OF COMMENTS. THE CONTRACTOR (QUALIFIER) THAT |
| | CREATED / DREW THE SET OF PLANS WILL NEED TO IDENTIFY |
| | THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE PRINT |
| | YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR THE |
| | TRADE YOU ARE LICENSED IN AND PLANS DRAWN. |
| | 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE |
| | EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H) |
| | ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C) |
| | (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT |
| | WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE |
| | CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE. |
| | THE CONTRACTOR (QUALIFIER) THAT CREATED / DREW THE SET |
| | OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR |
| | OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME |
| | AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN |
| | AND PLANS DRAWN. |
| | FOR EACH TRADE THE CONTRACTOR RESPONSIBLE FOR THE |
| | DESIGN UNDER THE TRADE LICENSED IN MUST PRINT THEIR |
| | NAME, SIGN THEIR NAME AND LICENSE NUMBER, NOTE THESE |
| | PLANS APPEAR TO BE DRAWN BY ONE INDUVIAL, THEY WOULD |
| | HAVE TO BE LICENSED AS A BUILDING, ELECTRICAL AND |
| | PLUMBING CONTRACTOR TO SUBMIT ALL THESE TRADES UNDER |
| | ONE SHEET. |
| | |
| | 2 &3) 2ND REQUEST. PROVIDE AN ITEMIZED SHEET SHOWING |
| | THE SQUARE FOOTAGE OF TILE FOR ON THE FLOORS AND WALLS |
| | FOR ALL AREAS WHERE WORK IS TO OCCUR. THE PERMIT |
| | APPLICATION FROM COMPLETE CONSTRUCTION & DEVELOPMENT, |
| | LEFT THE DESCRIPTION OF WORK BLANK. THE DOLLAR AMOUNT |
| | IS ALSO BLANK. THE SCOPE OF WORK CANNOT BE DETERMINED |
| | WITH THE PERMIT APPLICATION AND SUBMITTED PLANS. |
| | |
| | THE DOLLAR VALUE FOR THIS PERMIT CURRENTLY CANNOT |
| | SUBSTANTIATE WORK TO BE ACCOMPLISHED AT THIS TIME. |
| | 109.3 BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE |
| | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| | AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| | REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| | NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 4) COMPLIED. |
| | W. P. B. BUILDING DEPARTMENT HAS |
| | ALL (3) REQUIRED TEST ON FILE AT CITY HALL |
| | ON (F) DRIVE FLOOR UNDERLAYMENTS FOR: |
| | |
| | WHISPER MAT CS /TILE OR MARBLE |
| | IIC = 50 DB / 6 INCH SLAB P. T. / NO DROPPED CEILING / |
| | ASTM E-492 |
| | STC = 55 DB / 6 INCH SLAB P. T./ NO DROPPED / CEILING |
| | ASTM E-90 |
| | FLAME= 0 ASTM-E84 |
| | SMOKE= 35 ASTM E-84 |
| | J. WITMER BUILD PLAN REVIEW |
| | |
| | 5) COMPLIED. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ |
| | RETIRED. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |