2020-11-10 10:06:49PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
 GARAGE ( TYPE 1A ) / DETACHED PRIVATE GARAGE BUILDING
 (8 UNITS)
 TYPE V-B CONSTRUCTION, UNSPRINKLERED
 GROUP U OCCUPANCY
  
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THIS PROJECT IS IN A SPECIAL FLOOD HAZARD AREA, AE.
 THE BFE IS 14' NAVD88 AND THE DFE IS 16' NAVD88. THE
 FINISH FLOOR ELEVATION OF THE GARAGE IS SPECIFIED AS
 15' NAVD88. THIS IS ONE FOOT BELOW THE REQUIRED DFE AND
 WILL BE REQUIRED TO BE DESIGNED WITH FLOOD VENTS OR BE
 FLOOD PROOFED. PROVIDE A DESIGN THAT COMPLIES WITH THE
 CITY'S FLOOD ORDINANCE. SPECIFY THE PROPOSED ELEVATION
 OF THE GARAGE SLAB, IN NAVD 88 VERTICAL DATUM, ON THE
 ARCHITECTURAL PLANS. FBC 1612
  
 2) PROVIDE A DETAIL FOR THE REQUIRED ONE HOUR FIRE
 RESISTIVE RATED CEILING ASSEMBLY AND THE LISTING
 INFORMATION. FBC 711
  
 3) PROVIDE A DETAIL FOR THE LISTED JOINT TREATMENT THAT
 WILL BE USED AT THE INTERSECTION OF THE ONE HOUR FIRE
 RESISTIVE RATED THE INTERIOR WALLS AND CEILINGS. FBC
 715
  
 4) SECTION 4.2 ON THE GEOTECHNICAL REPORT STATES THAT
 THE FOOTINGS SHOULD BOTTOM AT LEAST 18" BELOW FINAL
 GRADE. SHOW HOW THIS BUILDING WILL MEET THIS
 REQUIREMENT. FBC 107.2
  
 5) WALL SECTION 2 ON SHEET GA-1, SHOWS THE BOTTOM OF
 THE FOOTER 8" BELOW GRADE. FBC REQUIRES THE BOTTOM OF
 FOOTINGS TO BE A MINIMUM OF 12" BELOW GRADE. FBC 1809.5
  
 6) ON SHEET GA-1A THE FIRE RATED WALLS, TYPE L, BETWEEN
 THE GARAGE UNITS ARE SPECIFIED AS 8" MASONRY. DETAIL
 S-GA-1A.2 IS FOR A 4" X 4" CONCRETE CAP AT THESE
 LOCATIONS WITH ONLY THE CONCRETE SLAB AND NO FOOTING.
 PLEASE COORDINATE. FBC 107.2
  
 7) PROVIDE STRUCTURAL DETAILS FOR THE TYPE L FIRE RATED
 MASONRY WALLS BETWEEN THE GARAGES. SPECIFY THE FOOTING,
 WALL AND TIE BEAM REINFORCING. FBC 2101
  
 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, ROOF VENTS, SWING DOORS AND OVERHEAD
 GARAGE DOORS. THESE ITEMS CAN BE DEFERRED IF REQUESTED,
 HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED
 BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 9) SUBMIT TRUSS DRAWINGS AND A TRUSS LAYOUT PLAN. FBC
 2303.4 THESE ITEMS CAN BE DEFERRED IF REQUESTED,
 HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED
 BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 10) ACCESSIBLE CAR AND VAN PARKING SPACES ARE REQUIRED
 TO BE A MINIMUM OF 12' WIDE AND HAVE A MINIMUM 60" WIDE
 ACCESS AISLE. SHOW COMPLIANCE WITH FBC ACCESSIBILITY
 502.2 AND 502.3.1
  
 11) FBC ACCESSIBILITY 502.4 REQUIRES THE ACCESSIBLE
 PARKING SPACE AND ACCESS AISLE TO HAVE A SLOPE NOT
 STEEPER THAN 1:48. THE SLOPE ON SHEET GA-1A IS
 SPECIFIED AS 1:20.
  
 12) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  