Plan Review Notes
Plan Review Notes For Permit 20100732
Permit Number 20100732
Review Stop G
Sequence Number 1
Notes
Date Text
2020-12-01 17:23:1912/01/20 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE TABLE USED FOR SIZING PIPE REQUIRES 1? FOR THE 2
 COOKING GRILL PLEASE PROVIDE A CORRECT TABLE AS THE
 BTU?S TOTAL 150 NOT 75 PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. THE DISTANCE FOR THE PIPE ON THE FIRE PLACE IS NOT
 LABEL PLEASE PROVIDE PER THE WPB AMENDMENTS TO THE FBC
 SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. REGULATORS INSTALLED OUTDOORS SHALL BE DESIGNED,
 INSTALLED, OR PROTECTED SO THEIR OPERATION WILL NOT BE
 AFFECTED BY THE ELEMENTS. PROVIDE DOCUMENTATION FROM
 THE MANUFACTURER THAT THE REGULATORS ARE APPROVED FOR
 EXTERIOR USE PER THE NFPA 58-11 SEC. 6.8.1.5.
  
 4. PLEASE PROVIDE SPECIFICATION FOR GAS GRILLS AND
 DETAIL OF VENTING UNDER CABINET FORM MANUFACTURES
 SPECIFICATION PER THE 2017 FBC FG SEC.305.1.
  
 5. PLEASE PROVIDE SPECIFICATION FOR FIRE PLACE PER THE
 2017 FBC FG SEC.305.1.
  
 6. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1? OF
 EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2 OR 2017
 FBC FG SEC 410.2.
  
 7. ON PPP-1 IT SHOWS THE LINES TO THE GRILLS ON 1/2?
 AND ON THE ISOMETRIC ON PPP-2 IT IS 3/4? PLEASE CORRECT
 AND RE0LABEL PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  