| Date |
Text |
| 2022-10-04 11:10:15 | RENOVATION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) DRAWING S004 SHOWS THE DESIGN WIND SPEED AT 169 MPH |
| | - RISK CATEGORY II DESIGN WIND SPEED NEEDS TO BE 170 |
| | MPH - FBC WBP SECTION 120 |
| | |
| | 2) PLEASE SHOW IF TERMITE PREVENTION IS REQUIRED FOR |
| | THE SOIL BELOW THE SLAB REPAIR - FBC 1816.1.2 |
| | |
| | 3) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVAL FOR THE EXTERIOR DOORS AND WINDOWS - |
| | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.3.4 |
| | |
| | 4) ACCESSIBLE RESTROOMS = PLEASE SHOW THE TOILET PAPER |
| | DISPENSER LOCATION FROM THE FRONT OF THE TOILET TO THE |
| | CENTER OF THE DISPENSER - FBC A 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. |
| | |
| | 5) PLEASE SHOW THE ACCESSIBLE ROUTE FROM THE PARKING TO |
| | THE ACCESSIBLE ENTRY - FBC A 206.4.1 PUBLIC ENTRANCES. |
| | IN ADDITION TO ENTRANCES REQUIRED BY 206.4.2 THROUGH |
| | 206.4.9, AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES |
| | SHALL COMPLY WITH 404. FBC A 206.2.1 SITE ARRIVAL |
| | POINTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED |
| | WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND |
| | ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS AND |
| | SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE |
| | ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. |
| | |
| | 6) FBC A 208.3.1 PARKING SPACES COMPLYING WITH 502 THAT |
| | SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE |
| | LOCATED ON THE SHORTEST ACCESSIBLE ROUTE FROM PARKING |
| | TO AN ENTRANCE COMPLYING WITH 206.4. ALL SPACES MUST BE |
| | LOCATED ON AN ACCESSIBLE ROUTE THAT IS AT LEAST 44 |
| | INCHES (1118 MM) WIDE AND SO THAT USERS ARE NOT |
| | COMPELLED TO WALK OR WHEEL BEHIND PARKED VEHICLES |
| | EXCEPT BEHIND HIS OR HER OWN VEHICLE. |
| | |
| | 7) A SEPARATE PERMIT IS REQUIRED FOR THE PARKING LOT. |