2020-10-28 10:08:20SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE ADDITION OF NO. 15 ASPHALT FELT ON
 THE EXTERIOR PLYWOOD PER FBC R703.2 WATER-RESISTIVE
 BARRIER.
 ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND
 BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR
 OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED
 OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS.
 2) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS
 AND ROOFING SYSTEM.
 3) DRAWING (A-3) SHOWS WIND DESIGN USING EXPOSURE "C" -
 DRAWING (A-4) SHOWS WIND DESIGN USING EXPOSURE "B" -
 PLEASE CLARIFY
  
  