| Notes |
| Date |
Text |
| 2020-10-31 11:48:26 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | | | | BUILDING REVIEW DENIED: | | | | | | PLEASE CLARIFY AND PROVIDE INFORMATION ON A SCHEDULE AS | | | NOTED BELOW: | | | | | | FBC B 107.2.1, PRODUCT APPROVAL # 16893-R5, PAGE #18 | | | HAS BEEN MARKED FOR A SPAN OF 60" FOR A 9" O.C. ANCHOR | | | SPACING BUT THE PROVIDED WINDLOAD CHART INDICATES THE | | | SPAN SHOULD BE AT A SPAN OF 96" FOR ANCHOR SPACING OF | | | 6" O.C.. | | | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE FACTORS APPLY DEPENDING ON SUBSTRATE, EDGE | | | DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, | | | BE SPECIFIC AS TO WHICH TAPCON. | | | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | | R 310.4; INCLUDE ROOM DESIGNATION. | | | |
|