| Date |
Text |
| 2020-10-23 15:39:57 | NEW SFR |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected]. |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) PLEASE SHOW AT LEAST 1 BATHROOM DOOR WIDTH TO COMPLY |
| | WITH FBC R320.1.1 ALL NEW SINGLE-FAMILY HOUSES, |
| | DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL |
| | PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM |
| | POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED ON |
| | HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29-INCH |
| | (737 MM) CLEAR OPENING. FBC ACCESSIBILITY 404.2.3 CLEAR |
| | OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE |
| | MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, |
| | WITH THE DOOR OPEN 90 DEGREES. ( A 2'6" DOOR DOES NOT |
| | COMPLY) |
| | 2) PLEASE SHOW THE ATTIC ACCESS LOCATION AND SIZE TO |
| | COMPLY WITH FBC R807 |
| | 3) PLEASE SHOW THE ATTIC VENTILATION TO COMPLY WITH FBC |
| | R806 |
| | 4) PLEASE SHOW THE BUILDING SQUARE FOOTAGE ON THE |
| | DRAWING. |
| | 5) ALL DRAWINGS NEED TO BE SIGNED AND SEALED BY THE |
| | ARCHITECT OR ENGINEER. FBC 107.1 |
| | 6) PLEASE PROVIDE THE FRONT PAGES (MIAMI DADE OR |
| | FLORIDA STATE) FOR THE DOOR PRODUCT APPROVAL. |
| | (INSTALLATION INSTRUCTIONS HAVE BEEN PROVIDED). |
| | 7) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING |
| | THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE |
| | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY |
| | PROPOSED WATER RETAINING SWALES) |
| | |
| | |
| | |