Plan Review Notes
Plan Review Notes For Permit 20100210
Permit Number 20100210
Review Stop Z
Sequence Number 2
Notes
Date Text
2020-12-03 17:28:08FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 SOUTH FACADE
  
 SIGNS CL.1 AND CL.2 ARE FASCIA IDENTITY SIGNS
  
 1) REPEAT COMMENT: THE ROSEMARY SQUARE SIGN CRITERIA
 PROHIBIT ROOFTOP SIGNS. SIGN CL-1 IS MOUNTED ON THE
 ROOF OF THE PATIO COVER BUILDING EXTENSION, SO AS THE
 SIGN IS PROPOSED, IT IS NOT PERMITTED. SINCE THE
 ROSEMARY SQUARE SIGN CRITERIA REQUIRE THAT FASCIA SIGNS
 BE MOUNTED TO THE BASE BUILDING FASCIA SIGN BAND AREA,
 A WAIVER 1 WOULD BE REQUIRED TO MOUNT THE SIGN ON THE
 FASCIA OF THE PATIO COVER BUILDING EXTENSION. PLEASE
 NOTE THAT THE PATIO COVER BUILDING EXTENSION DOES NOT
 MEET THE DEFINITION OF A CANOPY IN THE ROSEMARY SQUARE
 SIGN CRITERIA, SO THE CANOPY SIGN CRITERIA SO NOT APPLY
 TO THIS SIGN. NOTE: THE SIGN PANEL CONTAINING THE
 ELECTRICAL CONNECTIONS TO WHICH THE LETTERS ARE SHOWN
 MOUNTED TO IS PART OF THE SIGN. YOU CONTINUE TO SHOW
 THE SIGN MOUNTED TO THE ROOF WHICH IS NOT PERMITTED.
  
 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA PERMIT A MAXIMUM PANEL HEIGHT OF 18 INCHES FOR
 A FASCIA IDENTITY SIGN UNLESS SUBMITS AND IS GRANTED A
 WAIVER II (MINOR PLANNED DEVELOPMENT AMENDMENT). THE
 WAIVER II MAY INCREASE THE FASCIA IDENTITY SIGN HEIGHT
 BY UP TO 50 PERCENT, SO THE PANEL HEIGHT MAY BE A
 MAXIMUM OF 27 INCHES. NOTE: A MINOR AMENDMENT IS
 REQUIRED TO BE SUBMITTED TO THE PLANNING DIVISION
 UTILIZING THE DEVELOPMENT APPLICATION, NOT VIA A LETTER
 WITH THE BUILDING PERMIT. PLEASE CONTACT ME FOR A COPY
 OF THE APPLICATION.
  
 A. THE CURRENT DESIGN FOR SIGN CL.1 SHOWS A PANEL
 HEIGHT OF 36 INCHES, WHICH IS NOT PERMITTED.
 B. THE CURRENT DESIGN FOR SIGN CL.2 SHOWS A PANEL
 HEIGHT OF 28 INCHES, WHICH IS NOT PERMITTED.
  
 3) SIGN CL.1 INCLUDES BOTH THE COPY AND THE PANEL THAT
 IT IS MOUNTED TO, WHICH MAKES THIS SIGN 62 SQUARE FEET
 IN AREA.
  
 4) SIGN CL.2 INCLUDES BOTH THE COPY AND THE PANEL THAT
 IT IS MOUNTED TO, WHICH MAKES THE SIGN 19.2 SQUARE FEET
 IN AREA.
  
 5) REPEAT COMMENT: THE "LUCID" SIGN THAT IS SHOWN ON
 THE BUILD OUT PLANS MOUNTED ON TO THE INTERIOR WALL BUT
 VISIBLE ON THE EXTERIOR OF THE BUILDING IS REQUIRED TO
 COUNT TOWARD MEETING THE SIGN SQUARE FOOTAGE ALLOWANCE.
 PROVIDE A SHEET SHOWING THIS SIGN AND ITS DIMENSIONS.
 PLEASE NOTE THAT BASED ON THE EXTERIOR SIGNS, THIS SIGN
 MAY BE A MAXIMUM OF 31.6 SQUARE FEET IN AREA.
  
 PERMITTED: 132 SF
 PROPOSED CL.1: 62 SF - NOTE THIS SIGN AS CURRENTLY
 DESIGNED AS A ROOFTOP SIGN WHICH IS PROHIBITED
 PROPOSED EASTERN CL.2: 19.2 SF
 PROPOSED WESTERN CL.2: 19.2 SF
 TOTAL EXTERIOR: 100.4 SF
 INTERIOR VISIBLE WALL SIGN: UNKNOWN - MAX 31.6 SF
 PERMITTED
  
 6) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE ALL CONDUIT, RACEWAYS, WIRING, BALLAST
 BOXES, TRANSFORMERS, AND OTHER EQUIPMENT NECESSARY FOR
 SIGN CONNECTION SHALL BE CONCEALED. THE SECTION VIEW OF
 SIGN CL-1 SHOWS THE CONDUIT COMING OUT OF THE ROOF
 GOING TO THE FRONT OF THE SIGN PANEL, WHICH IS NOT
 PERMITTED. WHEN THIS SIGN IS REDESIGNED TO MEET THE
 FASCIA IDENTITY SIGN CRITERIA, THEN THIS CONDUIT NEEDS
 TO BE CONCEALED IN THE SIGN SUPPORT POSTS.
  
 7) REPEAT COMMENT: FOR SIGN CL-1 PROVIDE THE DETAILS OF
 THE CABINET HOUSING THE POWER SUPPLY TO WHICH THE SIGN
 COPY IS ATTACHED, TO IN INCLUDE TYPE OF METAL, COLOR
 AND FINISH.
  
 8) REPEAT COMMENT: FOR SIGN CL-2 PLEASE PROVIDE DETAILS
 OF THE METAL PANEL BEING INSTALLED AS THE BACKER TO THE
 LUCID COPY, TO INCLUDE TYPE OF METAL, COLOR AND FINISH.
  
 9) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THAT REVERSE CHANNEL LETTERS ARE
 FABRICATED OUT OF ALUMINUM WITH A MINIMUM METAL
 THICKNESS OF .060 INCHES WITH A PAINTED FINISH. THE
 SIGN DETAIL SPECIFIES THAT THE LETTERS ARE 16 GAUGE
 STAINLESS STEEL THAT WILL NOT BE PAINTED. THE USE OF
 UNPAINTED STAINLESS STEEL IS AN ALTERNATIVE MATERIAL
 WHICH REQUIRES APPROVAL BY CITYPLACE RETAIL AS A WAIVER
 1.
  
 10) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THE STUD MOUNTS TO BE SERIES 316
 STAINLESS STEEL ANCHOR BOLTS. PROVIDE VERIFICATION OF
 THIS REQUIREMENT ON THE PLANS.
  
 WEST FACADE
  
 SIGN CL.2 IS A FASCIA IDENTITY SIGN
  
 1) THE ROSEMARY SQUARE SIGN CRITERIA REQUIRE ONLY
 PERMIT FASCIA IDENTITY SIGNS ON A CASE BY CASE BASIS,
 WHICH IS A WAIVER 1. A WAIVER I REQUIRES WRITTEN
 APPROVAL FROM CITYPLACE RETAIL. NOTE: WAIVER I LETTER
 DID NOT ADDRESS THE SIGN ON THE ROSEMARY AVENUE FACSIA.
  
 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A
 MAXIMUM PANEL HEIGHT OF 18 INCHES FOR A FASCIA IDENTITY
 SIGN UNLESS SUBMITS AND IS GRANTED A WAIVER II (MINOR
 PLANNED DEVELOPMENT AMENDMENT). THE WAIVER II MAY
 INCREASE THE FASCIA IDENTITY SIGN HEIGHT BY UP TO 50
 PERCENT, SO THE PANEL HEIGHT MAY BE A MAXIMUM OF 27
 INCHES. THE CURRENT DESIGN FOR SIGN CL.2 SHOWS A PANEL
 HEIGHT OF 28 INCHES, WHICH IS NOT PERMITTED. NOTE: A
 MINOR AMENDMENT IS REQUIRED TO BE SUBMITTED TO THE
 PLANNING DIVISION UTILIZING THE DEVELOPMENT
 APPLICATION, NOT VIA A LETTER WITH THE BUILDING PERMIT.
 PLEASE CONTACT ME FOR A COPY OF THE APPLICATION.
  
 3) SIGN CL.2 INCLUDES BOTH THE COPY AND THE PANEL THAT
 IT IS MOUNTED TO, WHICH MAKES THE SIGN 19.2 SQUARE FEET
 IN AREA.
  
 PERMITTED: 21.25 SF
 PROPOSED CL.2: 19.2 SF
  
  
 4) REPEAT COMMENT: FOR SIGN CL-2 PLEASE PROVIDE DETAILS
 OF THE METAL PANEL BEING INSTALLED AS THE BACKER TO THE
 LUCID COPY, TO INCLUDE TYPE OF METAL, COLOR AND FINISH.
  
 5) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THAT REVERSE CHANNEL LETTERS ARE
 FABRICATED OUT OF ALUMINUM WITH A MINIMUM METAL
 THICKNESS OF .060 INCHES WITH A PAINTED FINISH. THE
 SIGN DETAIL SPECIFIES THAT THE LETTERS ARE 16 GAUGE
 STAINLESS STEEL THAT WILL NOT BE PAINTED. THE USE OF
 UNPAINTED STAINLESS STEEL IS AN ALTERNATIVE MATERIAL
 WHICH REQUIRES APPROVAL BY CITYPLACE RETAIL AS A WAIVER
 1.
  
 6) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THE STUD MOUNTS TO BE SERIES 316
 STAINLESS STEEL ANCHOR BOLTS. PROVIDE VERIFICATION OF
 THIS REQUIREMENT ON THE PLANS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  