| Date |
Text |
| 2020-11-04 15:10:07 | FAILED |
| | |
| | SOUTH FACADE |
| | |
| | SIGNS CL.1 AND CL.2 ARE FASCIA IDENTITY SIGNS |
| | |
| | 1) THE ROSEMARY SQUARE SIGN CRITERIA REQUIRE ONLY |
| | PERMIT FASCIA IDENTITY SIGNS ON A CASE BY CASE BASIS, |
| | WHICH IS A WAIVER 1. A WAIVER I REQUIRES WRITTEN |
| | APPROVAL FROM CITYPLACE RETAIL. |
| | |
| | 2) THE ROSEMARY SQUARE SIGN CRITERIA DO NOT PERMIT |
| | MULTIPLE FASCIA IDENTITY SIGNS ON A FRONTAGE UNLESS |
| | CITYPLACE RETAIL APPROVES THE USE OF MULTIPLE SIGNS AS |
| | A WAIVER 1. |
| | |
| | 3) THE ROSEMARY SQUARE SIGN CRITERIA PROHIBIT ROOFTOP |
| | SIGNS. SIGN CL-1 IS MOUNTED ON THE ROOF OF THE PATIO |
| | COVER BUILDING EXTENSION, SO AS THE SIGN IS PROPOSED, |
| | IT IS NOT PERMITTED. SINCE THE ROSEMARY SQUARE SIGN |
| | CRITERIA REQUIRE THAT FASCIA SIGNS BE MOUNTED TO THE |
| | BASE BUILDING FASCIA SIGN BAND AREA, A WAIVER 1 WOULD |
| | BE REQUIRED TO MOUNT THE SIGN ON THE FASCIA OF THE |
| | PATIO COVER BUILDING EXTENSION. PLEASE NOTE THAT THE |
| | PATIO COVER BUILDING EXTENSION DOES NOT MEET THE |
| | DEFINITION OF A CANOPY IN THE ROSEMARY SQUARE SIGN |
| | CRITERIA, SO THE CANOPY SIGN CRITERIA SO NOT APPLY TO |
| | THIS SIGN. |
| | |
| | 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| | MAXIMUM PANEL HEIGHT OF 18 INCHES FOR A FASCIA IDENTITY |
| | SIGN UNLESS SUBMITS AND IS GRANTED A WAIVER II (MINOR |
| | PLANNED DEVELOPMENT AMENDMENT). THE WAIVER II MAY |
| | INCREASE THE FASCIA IDENTITY SIGN HEIGHT BY UP TO 50 |
| | PERCENT, SO THE PANEL HEIGHT MAY BE A MAXIMUM OF 27 |
| | INCHES. |
| | |
| | A. THE CURRENT DESIGN FOR SIGN CL.1 SHOWS A PANEL |
| | HEIGHT OF 36 INCHES, WHICH IS NOT PERMITTED. |
| | B. THE CURRENT DESIGN FOR SIGN CL.2 SHOWS A PANEL |
| | HEIGHT OF 28 INCHES, WHICH IS NOT PERMITTED. |
| | |
| | 5) SIGN CL.1 INCLUDES BOTH THE COPY AND THE PANEL THAT |
| | IT IS MOUNTED TO, WHICH MAKES THIS SIGN 62 SQUARE FEET |
| | IN AREA. |
| | |
| | 6) SIGN CL.1 EXCEEDS THE 16 FOOT MAXIMUM HEIGHT FROM |
| | GRADE ALLOWED FOR A FASCIA IDENTITY SIGN. IF THIS SIGN |
| | IS REDESIGNED TO COMPLY WITH THE FASCIA IDENTITY SIGN |
| | REQUIREMENTS, AND IS STILL EXCEEDS THE 16 FOOT HEIGHT |
| | ALLOWANCE, CITYPLACE RETAIL MAY GRANT A WAIVER 1 FOR |
| | THE ALTERNATIVE VERTICAL PLACEMENT OF THE SIGN. |
| | |
| | 7) SIGN CL.2 INCLUDES BOTH THE COPY AND THE PANEL THAT |
| | IT IS MOUNTED TO, WHICH MAKES THE SIGN 19.2 SQUARE FEET |
| | IN AREA. |
| | |
| | 8) THE "LUCID" SIGN THAT IS SHOWN ON THE BUILD OUT |
| | PLANS MOUNTED ON TO THE INTERIOR WALL BUT VISIBLE ON |
| | THE EXTERIOR OF THE BUILDING IS REQUIRED TO COUNT |
| | TOWARD MEETING THE SIGN SQUARE FOOTAGE ALLOWANCE. |
| | PROVIDE A SHEET SHOWING THIS SIGN AND ITS DIMENSIONS. |
| | PLEASE NOTE THAT BASED ON THE EXTERIOR SIGNS, THIS SIGN |
| | MAY BE A MAXIMUM OF 31.6 SQUARE FEET IN AREA. |
| | |
| | PERMITTED: 132 SF |
| | PROPOSED CL.1: 62 SF - NOTE THIS SIGN AS CURRENTLY |
| | DESIGNED AS A ROOFTOP SIGN WHICH IS PROHIBITED |
| | PROPOSED EASTERN CL.2: 19.2 SF |
| | PROPOSED WESTERN CL.2: 19.2 SF |
| | TOTAL EXTERIOR: 100.4 SF |
| | INTERIOR VISIBLE WALL SIGN: UNKNOWN ? MAX 31.6 SF |
| | PERMITTED |
| | |
| | 9) THE ROSEMARY SQUARE SIGN CRITERIA PERMIT THREE |
| | COLORS ON A SIGN. |
| | |
| | A. FOR SIGN CL.1 PROVIDE THE COLOR OF THE SIGN CABINET |
| | HOUSING THE POWER SUPPLY TO WHICH THE SIGN COPY IS |
| | ATTACHED. THE LETTERS ARE LISTED AS STAINLESS STEEL |
| | WITH #6 FINISH AND WHITE ACRYLIC. ONLY ONE ADDITIONAL |
| | ALTERNATIVE COLOR IS PERMITTED, UNLESS A WAIVER I IS |
| | GRANTED BY CITYPLACE RETAIL. |
| | B. FOR SIGN CL.2 PROVIDE THE COLORS OF THE CABINET AND |
| | THE METAL PANEL. THE LETTERS ARE LISTED AS STAINLESS |
| | STEEL WITH #6 FINISH AND WHITE ACRYLIC. ONLY ONE |
| | ADDITIONAL ALTERNATIVE COLOR IS PERMITTED, UNLESS A |
| | WAIVER I IS GRANTED BY CITYPLACE RETAIL. |
| | |
| | 10) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | ALL CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, |
| | TRANSFORMERS, AND OTHER EQUIPMENT NECESSARY FOR SIGN |
| | CONNECTION SHALL BE CONCEALED. THE SECTION VIEW OF SIGN |
| | CL-1 SHOWS THE CONDUIT COMING OUT OF THE ROOF GOING TO |
| | THE FRONT OF THE SIGN PANEL, WHICH IS NOT PERMITTED. |
| | WHEN THIS SIGN IS REDESIGNED TO MEET THE FASCIA |
| | IDENTITY SIGN CRITERIA, THEN THIS CONDUIT NEEDS TO BE |
| | CONCEALED IN THE SIGN SUPPORT POSTS. |
| | |
| | 11) FOR SIGN CL-1 PROVIDE THE DETAILS OF THE CABINET |
| | HOUSING THE POWER SUPPLY TO WHICH THE SIGN COPY IS |
| | ATTACHED, TO IN INCLUDE TYPE OF METAL, COLOR AND |
| | FINISH. |
| | |
| | 12) FOR SIGN CL-2 PLEASE PROVIDE DETAILS OF THE METAL |
| | PANEL BEING INSTALLED AS THE BACKER TO THE LUCID COPY, |
| | TO INCLUDE TYPE OF METAL, COLOR AND FINISH. |
| | |
| | 13) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF |
| | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES |
| | WITH A PAINTED FINISH. THE SIGN DETAIL SPECIFIES THAT |
| | THE LETTERS ARE 16 GAUGE STAINLESS STEEL THAT WILL NOT |
| | BE PAINTED. THE USE OF UNPAINTED STAINLESS STEEL IS AN |
| | ALTERNATIVE MATERIAL WHICH REQUIRES APPROVAL BY |
| | CITYPLACE RETAIL AS A WAIVER 1. |
| | |
| | 14) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THE STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR |
| | BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE |
| | PLANS. |
| | |
| | WEST FACADE |
| | |
| | SIGN CL.2 IS A FASCIA IDENTITY SIGN |
| | |
| | 1) THE ROSEMARY SQUARE SIGN CRITERIA REQUIRE ONLY |
| | PERMIT FASCIA IDENTITY SIGNS ON A CASE BY CASE BASIS, |
| | WHICH IS A WAIVER 1. A WAIVER I REQUIRES WRITTEN |
| | APPROVAL FROM CITYPLACE RETAIL. |
| | |
| | 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| | MAXIMUM PANEL HEIGHT OF 18 INCHES FOR A FASCIA IDENTITY |
| | SIGN UNLESS SUBMITS AND IS GRANTED A WAIVER II (MINOR |
| | PLANNED DEVELOPMENT AMENDMENT). THE WAIVER II MAY |
| | INCREASE THE FASCIA IDENTITY SIGN HEIGHT BY UP TO 50 |
| | PERCENT, SO THE PANEL HEIGHT MAY BE A MAXIMUM OF 27 |
| | INCHES. THE CURRENT DESIGN FOR SIGN CL.2 SHOWS A PANEL |
| | HEIGHT OF 28 INCHES, WHICH IS NOT PERMITTED. |
| | |
| | 3) SIGN CL.2 INCLUDES BOTH THE COPY AND THE PANEL THAT |
| | IT IS MOUNTED TO, WHICH MAKES THE SIGN 19.2 SQUARE FEET |
| | IN AREA. |
| | |
| | 4) THE ROSEMARY SQUARE SIGN CRITERIA MEASURES SIGNAGE |
| | ALLOWANCE AS FOLLOWS - ONE SQUARE FOOT OF SIGNAGE FOR |
| | EACH ONE LINEAR FOOT OF STORE FRONTAGE. PLEASE PROVIDE |
| | THE LINEAR FEET OF STORE FRONTAGE. |
| | |
| | PERMITTED: UNKNOWN |
| | PROPOSED CL.2: 19.2 SF |
| | |
| | 5) THE ROSEMARY SQUARE SIGN CRITERIA PERMIT THREE |
| | COLORS ON A SIGN. PROVIDE THE COLORS OF THE CABINET AND |
| | THE METAL PANEL. THE LETTERS ARE LISTED AS STAINLESS |
| | STEEL WITH #6 FINISH AND WHITE ACRYLIC. ONLY ONE |
| | ADDITIONAL ALTERNATIVE COLOR IS PERMITTED, UNLESS A |
| | WAIVER I IS GRANTED BY CITYPLACE RETAIL. |
| | |
| | 6) FOR SIGN CL-2 PLEASE PROVIDE DETAILS OF THE METAL |
| | PANEL BEING INSTALLED AS THE BACKER TO THE LUCID COPY, |
| | TO INCLUDE TYPE OF METAL, COLOR AND FINISH. |
| | |
| | 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF |
| | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES |
| | WITH A PAINTED FINISH. THE SIGN DETAIL SPECIFIES THAT |
| | THE LETTERS ARE 16 GAUGE STAINLESS STEEL THAT WILL NOT |
| | BE PAINTED. THE USE OF UNPAINTED STAINLESS STEEL IS AN |
| | ALTERNATIVE MATERIAL WHICH REQUIRES APPROVAL BY |
| | CITYPLACE RETAIL AS A WAIVER 1. |
| | |
| | 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE |
| | STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR |
| | BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE |
| | PLANS. |
| | |