| Date |
Text |
| 2021-02-05 16:34:13 | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT- 20100064 |
| | 12/22/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | COMMENT #2 FROM THE 1ST AND 2ND REVIEW STILL EXISTS. |
| | BASED ON THE CODE SECTIONS REFERENCED IN THE COMMENT, |
| | THE SINGLE USER BATHROOMS IN THE SPECIAL VISITORS AND |
| | SICKLE CELL FOUNDATION AREAS CANNOT BE LABELED AS |
| | UNISEX BECAUSE THE WATER CLOSETS IN THOSE ROOMS SHALL |
| | BE GENDER SPECIFIC IN ORDER TO MEET THE REQUIRED NUMBER |
| | OF TWO MALE AND TWO FEMALE WATER CLOSETS EACH FOR THE |
| | BUSINESS OCCUPANCY AND OCCUPANT LOAD. |
| | |
| | 2) PROVIDE PLUMBING FIXTURE CALCULATIONS IN ACCORDANCE |
| | WITH TABLE 403.3 FBC P. PLEASE NOTE THE OCCUPANT LOAD |
| | OF THE FACILITY IS BEING QUESTIONED BY THE BUILDING |
| | PLAN REVIEWER. AN INCREASED OCCUPANT LOAD COULD RESULT |
| | IN INCREASED FIXTURE REQUIREMENTS- TABLE 403.3 FBC P. |
| | THE PLUMBING FIXTURE CALCULATIONS ON SHEET A2.1 |
| | INDICATE UNISEX WATER CLOSETS ARE PROVIDED TO MEET THE |
| | REQUIREMENT OF TWO MALE AND TWO FEMALE WATER CLOSETS. |
| | BASED ON SECTIONS 403.1.1, 403.1.2, AND 403.2.1 FBC P |
| | THE PLUMBING FIXTURES AND RESTROOMS SHALL BE IDENTIFIED |
| | AS EITHER MALE OR FEMALE. THE EXCEPTION UNDER SECTION |
| | 403.2.1 APPLIES TO ASSEMBLY AND MERCANTILE OCCUPANCIES- |
| | SECTION 403.1.2 FBC P: FIXTURES LOCATED WITHIN FAMILY |
| | OR ASSISTED-USE TOILET AND BATHING ROOMS REQUIRED BY |
| | THE FLORIDA BUILDING CODE, ACCESSIBILITY ARE PERMITTED |
| | TO BE INCLUDED IN THE NUMBER OF REQUIRED FIXTURES FOR |
| | EITHER THE MALE OR FEMALE OCCUPANTS IN ASSEMBLY AND |
| | MERCANTILE OCCUPANCIES. SECTION 403.2.1 STATES FAMILY |
| | OR ASSISTED-USE TOILET FACILITIES SHALL NOT BE REQUIRED |
| | TO BE IDENTIFIED FOR EXCLUSIVE USE BY EITHER SEX AS |
| | REQUIRED BY SECTION 403.4- REQUIRED PUBLIC FACILITIES |
| | SHALL BE PROVIDED WITH SIGNS THAT DESIGNATE THE SEX. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |
| 2021-02-02 09:32:27 | IN PROGRESS |
| | CCOLE- 2/2/21 |