Plan Review Notes
Plan Review Notes For Permit 20100054
Permit Number 20100054
Review Stop B
Sequence Number 2
Notes
Date Text
2020-10-30 11:19:20WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20100054
 ADD: 1801 N. FLAGLER DR. # 611
 CONT: FACE OF WOODS
 TEL: 954-663-8000
 E-MAIL: INFO@FACEOF WOOD.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,
 BUILDING.
  
 2ND REVIEW
 DATE: FRI. OCT. 30TH/ 2020
 ACTION: DENIED
  
 1) COMPLIED. CERTIFICATION BY CONTRACTOR.
  
 2) CONTRACTOR PLEASE NOTE THE SUBMITTED ECO- ULTRA
 QUIET UNDERLAYMENT YOU SUBMITTED, THE CITY BUILDING
 DEPARTMENT HAS NONE OF THE (3) REQUIRED TEST RESULTS
 FOR THIS PRODUCT. YOU HAVE IN THE PAST SUBMITTED FOR:
 PERMIT: 17060730 ECO ULTIMATE SILENCER, WE HAVE REPORTS
 FOR WOOD IIC-52, STC-51 AND LUXURY VINYL IIC-52,
 STC-51.
 PERMIT: 16060720 LL ECO SILENT SOUND, WE HAVE REPORTS
 FOR LAMINATE FLOORING: IIC-52, STC -51, FLAME 55 &
 SMOKE 60.
 THE PRODUCTS LISTED ABOVE HAVE BEEN APPROVED YOU WOULD
 NEED TO NOTE THAT ON YOUR FLOOR PLAN WHICH PRODUCT YOU
 WOULD INTEND TO USE OR OTHERWISE NEED TO SUBMIT A
 PRODUCT THAT MEETS ALL 3 TEST, AND SUBMITALL 3 TEST!!!!
  
 THE CONTRACTOR HAS NOT IDENTIFIED WHAT TYPE OF FLOOR
 COVERING IS TO BE INSTALLED OVER THE FLOOR
 UNDERLAYMENT. TESTING REPORTS SHOULD INCLUDE THE FINISH
 FLOOR PRODUCT AND UNDERLAYMENT. FLOOR INSULATION (FBC-B
 2017) FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING
 ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED
 FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET
 THE QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS
 FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ NO DROPPED
 CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS SHOWING
 COMPLIANCE WITH:
  
 TYPE I AND II BUILDINGS
 2A) FBC-B 2017 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2017 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2017 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  