| 2020-10-06 07:50:16 | 1ST REVIEW FBC-2017 MECHANICAL |
| | PERMIT-20091353 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) PLEASE SHOW THAT THE RETURN AIR PATH IS BALANCED. |
| | FBC RES M1602.3 |
| | |
| | 2) PLEASE SHOW HOW THE DRYER WILL BE EXHAUSTED TO THE |
| | OUTDOORS. PROVIDE DUCT LENGTH FOR DRYER DUCT. FBC RES |
| | M1502 |
| | |
| | 3) THE WATER CLOSET AREA HAS AN EXHAUST FAN IN THE |
| | MASTER BATH AREA. PLEASE PROVIDE BATHROOM EXHAUST IN |
| | THE MASTER BATH. FBC RES TABLE M1507.4 |
| | |
| | 4) PLEASE SHOW THE RANGE HOOD MEETS FBC RES M1503.1 |
| | |
| | 5) PLEASE PROVIDE DETAILS FOR ANCHORING THE CONDENSING |
| | UNIT. FBC RES M1307.2 |
| | |
| | 6) PLEASE SHOW METHOD OF REMOVING CONDENSATION. FBC RES |
| | M1411.3 |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD |
| | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER |
| | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN |
| | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS |
| | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS |
| | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR |
| | UPDATED. |
| | |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |
| | [email protected] |
| | |