| Date |
Text |
| 2020-11-19 11:59:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20091250 |
| | ADD: 4400 N. CONGRESS AVE. SUITE: 100 |
| | CONT: BERG CONSTRUCTION |
| | TEL: 561-339-7827 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. NOV. 19TH/2020 |
| | ACTION: DENIED |
| | 1) COMPLIED. |
| | |
| | 2A) SEMI-COMPLIED. IN THE PASR THE DESIGN PROFESSIONAL |
| | DID CONTACT ME BY PHONE TO DISCUSS THIS PROJECT. I DID |
| | STATE THAT THE 20% DISPROPORTIONAT COST ($7,000.00 |
| | DOLLARS) WOULD NEED TO BE SPENT IN EITHER ONE UNISEX |
| | RESTROOM AND IF THAT COULD NOT BE COMPLETED FOR |
| | $7,000.00 DOLLARS IT WOULD NEED A LETTER STATING AS |
| | SUCH FOR THAT DOLLAR AMOUNT AND IN THAT LETTER SHOW |
| | WHERE THE $7,000.00 DOLLARS IS GOING TO BE SPENT. THIS |
| | LETTER IS NOT TO BE PART OF THE PLAN REVIEW COMMENTS |
| | BUT ON THEIR LETTERHEAD AND LOADED AS A SEPARATE |
| | DOCUMENT IN THE FILE FOLDER. THANK YOU FOR YOUR HELP IN |
| | THIS MATTER.. |
| | |
| | 1ST ROUND OF COMMENTS. SHEET A.1.1SHOWING 4 RESTROOMS |
| | AND NONE ARE SHOWN TO BE ACCESSIBLE RESTROOMS, NOT EVEN |
| | A SINGLE UNISEX RESTROOM. |
| | PLEASE REVIEW IN THE 2017 FBC-ACCESSIBILITY CODE |
| | CHAPTER 2 SCOPING REQUIREMENTS SECTION 213.2 FOR TOILET |
| | ROOMS AND BATHING ROOMS AND EXCEPTION 2 AND 4. |
| | |
| | 2B) THE PLANS INDICATE THIS ALTERATION IS DECLARED AS A |
| | LEVEL II ALTERATION. EXISTING BLDG. CODE- |
| | ACCESSIBILITY. UNDER THE 2017 EXISTING BUILDING CODE |
| | LEVEL II ALTERATIONS, SECTION 806.1 A BUILDING, |
| | FACILITY, OR ELEMENT THAT IS ALTERED SHALL COMPLY WITH |
| | THE PROVISIONS OF THE FLORIDA BUILDING CODE- |
| | ACCESSIBILITY. IN THE ACCESSIBILITY CODE FOR |
| | ALTERATIONS YOU ARE REFERRED TO SECTION 202.4.1 |
| | DISPROPORTIONATE COST AND 202.4.2 ACCESSIBLE FEATURES |
| | IN THE EVENT OF DISPROPORTIONALITY. |
| | |
| | THE CONTRACT VALUE FOR THIS JOB AS STATED IS $35,000.00 |
| | DOLLARS. FLORIDA ACCESSIBILITY CODE SECTION: |
| | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU |
| | ARE TO MEET DISPROPORTIONATE COST. EITHER THE |
| | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR |
| | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP |
| | TO THE 20% DISPROPORTIONATE FUNDS($35,000.00X0.20= |
| | $7,000.00) LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE |
| | BEING SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 |
| | DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE. |
| | |
| | 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED |
| | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL |
| | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE |
| | ALTERATION TO THE PRIMARY FUNCTION AREA. COST THAT MAY |
| | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COST |
| | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN |
| | ACCESSIBLE ROUT TO THE ALTERED AREA; (II) COST |
| | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS |
| | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, |
| | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET |
| | CONTROLS; (III) COST ASSOCIATED WITH PROVIDING |
| | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE |
| | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION |
| | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) |
| | COST ASSOCIATED WITH RELOCATING AN ACCESSIBLE DRINKING |
| | FOUNTAIN. |
| | IF IN THE EVENT THE CONTRACTOR REACHES DISPROPORTION |
| | COST THEN ON THEIR LETTERHEAD AGAIN THEY MUST SHOW |
| | WHERE UP TO $7,000.00 DOLLARS WILL BE SPENT IN |
| | ACCESSIBLE UPGRADES. IN REVIEWING THIS PLAN IT WOULD |
| | APPEAR THE FUNDS WOULD BE SPENT IN CREATING A UNISEX |
| | RESTROOM. |
| | |
| | 2B) NEW COMMENT. SHEET A3.1 DETAIL 4 DOES SHOW THE HIGH |
| | LOW DRINKING FOUNTAIN AND WITH THIS TYPE OF DRINKING |
| | FOUNTAIN THE LOW DRINKING FOUNTAIN MEETS THE PROTRUDING |
| | OBJECT REQUIREMENTS BUT AS SHOWN IF WALKING DOWN THE |
| | CORRIDOR FROM THE RIGHT THE BOTTOM OF THE UPPER |
| | DRINKING FOUNTAIN IS HIGHER THAN 27 INCHES AND NOT |
| | MEETING THE REQUIREMENTS OF THE 2017 FBC-ACCESSIBILITY |
| | CODE SECTION PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS |
| | 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES |
| | AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT |
| | PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE |
| | CIRCULATION PATH. |
| | |
| | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |