Plan Review Notes
Plan Review Notes For Permit 20091229
Permit Number 20091229
Review Stop B
Sequence Number 1
Notes
Date Text
2020-10-08 12:44:01ADD SHOWER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE PROVIDE AN EXISTING FLOOR PLAN.
 2) PLEASE WRITE THE SCOPE OF WORK ON THE DRAWING.
 3) DRAWING PROVIDED NEEDS TO BE SIGNED AND SEALED BY
 THE ARCHITECT. FBC 107.1
 4) PLEASE SHOW DETAILS FOR ANY ADDED WALLS.
 5) SHOW WALL COVERING (TILE?) R307.2 BATHTUB AND SHOWER
 SPACES.
 BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH
 INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL
 BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL
 SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6
 FEET (1829 MM) ABOVE THE FLOOR.
 6) SHOW WALL BOARD - R702.4.2BACKER BOARDS.
 MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND
 SHOWER AREAS AND WALL PANELS IN SHOWER AREAS SHALL BE
 OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN
 ACCORDANCE WITH THE MANUFACTURER?S RECOMMENDATIONS.
 TABLE R702.4.2
 BACKER BOARD MATERIALS
 MATERIAL STANDARD
 GLASS MAT GYPSUM BACKING PANEL ASTM C1178
 FIBER-REINFORCED GYPSUM PANELS ASTM C1278
 NONASBESTOS FIBER-CEMENT BACKER BOARD ASTM C1288 OR ISO
 8336, CATEGORY C
 NONASBESTOS FIBER MAT REINFORCED CEMENTITIOUS BACKER
 UNITS ASTM C1325


Account Summary | Usage Policy | Privacy Policy