| Plan Review Notes For Permit 20091229 |
| Permit Number |
20091229 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-10-08 12:44:01 | ADD SHOWER | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE AN EXISTING FLOOR PLAN. | | | 2) PLEASE WRITE THE SCOPE OF WORK ON THE DRAWING. | | | 3) DRAWING PROVIDED NEEDS TO BE SIGNED AND SEALED BY | | | THE ARCHITECT. FBC 107.1 | | | 4) PLEASE SHOW DETAILS FOR ANY ADDED WALLS. | | | 5) SHOW WALL COVERING (TILE?) R307.2 BATHTUB AND SHOWER | | | SPACES. | | | BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH | | | INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL | | | BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL | | | SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 | | | FEET (1829 MM) ABOVE THE FLOOR. | | | 6) SHOW WALL BOARD - R702.4.2BACKER BOARDS. | | | MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND | | | SHOWER AREAS AND WALL PANELS IN SHOWER AREAS SHALL BE | | | OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN | | | ACCORDANCE WITH THE MANUFACTURER?S RECOMMENDATIONS. | | | TABLE R702.4.2 | | | BACKER BOARD MATERIALS | | | MATERIAL STANDARD | | | GLASS MAT GYPSUM BACKING PANEL ASTM C1178 | | | FIBER-REINFORCED GYPSUM PANELS ASTM C1278 | | | NONASBESTOS FIBER-CEMENT BACKER BOARD ASTM C1288 OR ISO | | | 8336, CATEGORY C | | | NONASBESTOS FIBER MAT REINFORCED CEMENTITIOUS BACKER | | | UNITS ASTM C1325 |
|