Plan Review Notes
Plan Review Notes For Permit 20091176
Permit Number 20091176
Review Stop E
Sequence Number 2
Notes
Date Text
2020-11-17 10:21:22CODES IN EFFECT
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 REVIEW STATUS: APPROVED.
  
 PREVIOUS COMMENTS:
  
 1) PANEL SCHEDULE REQUIRED
  
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW CIRCUITS, THE
 WIRE AND BREAKER SIZE FOR THESE CIRCUITS, AND AFCI OR
 GFCI PROTECTION WHERE APPLICABLE TO COMPLY WITH CODE.
 NEC 210.8, 210.12, 215.5, 408.4; FBC RE3706.2, RE3902
  
 CORRECTED
  
 2) PROVIDE A LOAD CALCULATION PER 215.5
  
 PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL LOADS.
 NEC 220; FBC RE3602.3
  
 CORRECTED
  
 3) FEEDER TO PANEL WILL HAVE TO BE ROUTED UNDERGROUND
 FROM METER TO PANEL OR A MAIN WILL BE REQUIRED OUTSIDE
 AT METER.
  
 CORRECTED
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  
  