| Notes |
| Date |
Text |
| 2020-10-13 10:47:21 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVED WITH PROVISOS: | | | | | | 1) PROVIDE DESIGNER OF RECORD REVIEW STAMPED PRODUCT | | | APPROVAL FOR SLIDING GLASS DOOR. | | | 2) PROVIDE SIGNED/SEALED SPECIFIC DETAILS FOR TRUSS | | | REPAIR INCLUDING NUMBER OF FASTENERS FOR FOR GUSSET | | | PLATES. | | | 3) AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION | | | PLEASE PROVIDE A WELD PROCEDURE SPECIFICATION; THE | | | W.P.S. SPECIFIES THE REQUIRED ESSENTIAL VARIABLES | | | INCLUDING: BASE MATERIALS, JOINTS, PROCESS, AND FILLER | | | METALS TO BE USED. | | | AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | | | | |
|