| 2020-10-22 15:15:09 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 2ND REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ROOFING PRODUCT APPROVAL (FL16732-R17) IS APPROVED | | | FOR (HVHZ) ZONES ONLY - "HIGH VELOCITY HURRICANE ZONE" | | | WHICH THE BUILDING CODE REFERS TO DADE AND BROWARD | | | COUNTY ONLY. NOT APPROVED FOR WEST PALM BEACH. | | | 2) ROOFING PRODUCT APPROVAL (FL10626-R18) IS A ROOFING | | | UNDERLAYMENT ONLY - WHICH IS USED FOR UNDER SHINGLES, | | | TILE OR METAL ROOFING. | | | 3) ROOFING PRODUCT APPROVAL (NOA 18-1219.01) IS FOR USE | | | ON A "CEMENTITIOUS WOOD FIBER" ROOF DECK - YOUR PLANS | | | SHOW A " PLYWOOD" ROOF DECK. | | | 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | | CIRCLE THE ROOFING SYSTEM NUMBER TO BE USED IN THE | | | PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE SIGNED AND | | | SEALED ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT | | | OR ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY | | | REQUIRE A HIGHER WIND PRESSURE - SEE NOTES ON THE | | | PRODUCT APPROVAL. |
|