Plan Review Notes
Plan Review Notes For Permit 20090505
Permit Number 20090505
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-10-08 15:37:56FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 BLADE SIGN C (WEST FACADE)
  
 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMIT WALL
 MOUNTED BLADE SIGN PANELS TO HAVE A MAXIMUM SIGN FACE
 OF FOUR (4) SQUARE FEET. THE PROPOSED SIGN IS 4.04
 SQUARE FEET IN AREA. CITYPLACE RETAIL MAY APPROVE IN
 WRITING A WAIVER I TO INCREASE IN THE SIGN SQUARE
 FOOTAGE BY 25 PERCENT, WHICH WOULD PERMIT THIS SIGN AT
 THE PROPOSED SIZE.
  
 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT
 LEAST THREE (3) INCHES FROM ANY EDGE OF THE PERCEIVED
 SIGN AREA (TOP, SIDES AND BOTTOM). PROVIDE A DETAIL OF
 THE SIGN FACE THAT VERIFIES THIS REQUIREMENT.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT THE
 PUSH THROUGH LETTERS TO HAVE HALO ILLUMINATION. PLEASE
 VERIFY THAT THE PROPOSED LETTERS WILL HAVE HALO
 ILLUMINATION AND NOT BE ILLUMINATED LETTERS. IF THE
 LETTERS ARE TO BE ILLUMINATED, THEN CITYPLACE RETAIL
 MUST APPROVE IN WRITING A WAIVER I TO PERMIT THE
 ALTERNATE ILLUMINATION STYLE.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. THE PLANS DO NOT CLEARLY SHOW
 THAT THE WIRING IS LOCATED WITHIN THE MOUNTING TUBES
 LEADING TO THE INTERIOR OF THE SIGN PANEL. THIS NEEDS
 TO BE CLARIFIED.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO
 VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO
 AS TO BE UNNOTICEABLE. THE BOLT HEADS THAT EXTEND PAST
 THE MOUNTING PLATE DO NOT MEET THIS STANDARD. IF THE
 BOLT HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY
 NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE
 MOUNTING PLATE.
  
 6) HE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THAT
 ALL INSTALLATION COMPONENTS CONSIST OF ANODIZED
 ALUMINUM. PROVIDE ON THE PLANS VERIFICATION THAT THE
 MOUNTING PLATE AND TUBES, INCLUDING DECORATIVE FINIAL,
 ARE ANODIZED ALUMINUM.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS.
  
 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMITS THE
 SIGN COPY TO TRADE NAMES ONLY. THE LISTING OF
 MERCHANDISE OR DESCRIPTIONS OF CATEGORY OR THE
 ELABORATION OF THE COMPANY?S PRODUCTS OR SERVICES (THE
 TO GO SERVICE) IS ONLY PERMITTED AS A WAIVER I. A
 WAIVER I REQUIRES WRITTEN APPROVAL FROM CITYPLACE
 RETAIL.
  
 BLADE SIGN G (NORTH FACADE)
  
 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT
 LEAST THREE (3) INCHES FROM ANY EDGE OF THE PERCEIVED
 SIGN AREA (TOP, SIDES AND BOTTOM). PROVIDE A DETAIL OF
 THE SIGN FACE THAT VERIFIES THIS REQUIREMENT.
  
 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT THE
 PUSH THROUGH LETTERS TO HAVE HALO ILLUMINATION. PLEASE
 VERIFY THAT THE PROPOSED LETTERS WILL HAVE HALO
 ILLUMINATION AND NOT BE ILLUMINATED LETTERS. IF THE
 LETTERS ARE TO BE ILLUMINATED, THEN CITYPLACE RETAIL
 MUST APPROVE IN WRITING A WAIVER I TO PERMIT THE
 ALTERNATE ILLUMINATION STYLE.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. THE PLANS DO NOT CLEARLY SHOW
 THAT THE WIRING IS LOCATED WITHIN THE MOUNTING TUBES
 LEADING TO THE INTERIOR OF THE SIGN PANEL. THIS NEEDS
 TO BE CLARIFIED.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO
 VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO
 AS TO BE UNNOTICEABLE. THE BOLT HEADS THAT EXTEND PAST
 THE MOUNTING PLATE DO NOT MEET THIS STANDARD. IF THE
 BOLT HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY
 NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE
 MOUNTING PLATE.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT ALL INSTALLATION COMPONENTS CONSIST OF ANODIZED
 ALUMINUM. PROVIDE ON THE PLANS VERIFICATION THAT THE
 MOUNTING PLATE AND TUBES, INCLUDING DECORATIVE FINIAL,
 ARE ANODIZED ALUMINUM.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS.
  