| Plan Review Notes For Permit 20090458 |
| Permit Number |
20090458 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2020-09-25 14:15:54 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE CEILING HEIGHT AT THE BOTTOM OF THE | | | AC SOFFIT TO COMPLY WITH FBC R305.1MINIMUM HEIGHT.(7 | | | FEET) | | | 2) PLEASE SHOW THE REQUIRED DRYWALL AT THE AC CLOSET | | | CEILING AND WALLS TO COMPLY WITH FBC R302.7UNDER-STAIR | | | PROTECTION. | | | ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE | | | WALLS, UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON | | | THE ENCLOSED SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. | | | 3) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | | STATE PRODUCT APPROVAL FOR THE NEW EXTERIOR WINDOW. | | | (FRONT PAGES AND THE INSTALLATION INSTRUCTIONS) | | | 4) PLEASE SHOW THE WIND DESIGN DATA USED FOR THE WIND | | | DESIGN. FBC R301.2.1 | | | 5) PLEASE SHOW THE REQUIRED WIND PRESSURES FOR THE NEW | | | WINDOW OPENING. | | | 6) PLEASE PROVIDE FIREPLACE DETAILS TO COMPLY WITH FBC | | | R CHAPTER 10. |
|