| 2020-10-21 17:50:38 | RESIDENTIAL (R3)ADDITION, BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | 1-ENERGY CALCULATIONS SUBMITTED: |
| | ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED AT |
| | THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S |
| | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 6TH EDITION |
| | (2017). |
| | SEC. 507, SEC. 1106 FBC-EXISTING BUILDING |
| | |
| | 2- SHEET A-4: |
| | A)WINDOW AND DOORS WERE REMOVED TO ALLOW FOR THE |
| | PROPOSED ADDITION. PLANS DON'T SHOW LAYOUT OF THE |
| | EXISTING ROOMS ADJACENT TO THE PROPOSED ADDITION. |
| | PROVIDE LAYOUT OF THE EXISTING AREA ADJACENT TO THE |
| | PROPOSED ADDITION. SHOW THE SCOPE OF WORK ON THE |
| | EXISTING ROOMS. ARE THERE ANY BEDROOMS? IF SO, HOW IS |
| | THE EGRESS AFFECTED. SPECIFY TYPE AND SIZE OF EGRESS |
| | WINDOWS. |
| | SEC. 107.2.1 CITY AMENDMENTS. SEC. 507, SEC. 1101.1 |
| | FBC-EXISTING BUILDING. SEC. R310.2 FBC-RESIDENTIAL. |
| | |
| | B)IF EXISTING WINDOW IS IN A BATHROOM AND WAS CLOSED TO |
| | ALLOW FOR ADDITION, THEN NEED VENTILATION FOR EXISTING |
| | BATHROOM. SPECIFY EXHAUST FAN AS REQUIRED BY THE |
| | EXCEPTION ON SEC. R303.3 FBC-RESIDENTIAL. |
| | SEC. 107.2.1 CITY AMENDMENTS. SEC. 507, SEC. 1101.1 |
| | FBC-EXISTING BUILDING. |
| | |
| | 3- PROPERTY IS LOCATED IN QUESTIONABLE SOIL. NEED TO |
| | PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4 |
| | BC-RESIDENTIAL. |
| | SEC. 507, SEC. 1101.1 FBC-EXISTING BUILDING. |
| | |
| | 4- PLANS AND DETAILS DON'T PROVIDE INFORMATION FOR NEW |
| | SOFFITS. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS |
| | FOR THE SOFFIT INSTALLATION SHOWING COMPLIANCE WITH |
| | SEC. R703.1.2.1 FBC-RESIDENTIAL. SPECIFY MATERIALS AND |
| | FASTENING. |
| | SEC. 507, SEC. 1101.1 FBC-EXISTING BUILDING. |
| | |
| | 5- SPECIFY SIZE AND LOCATION OF SOFFIT VENTS SHOWING |
| | COMPLIANCE WITH SEC. R806 FBC-RESIDENTIAL. PLANS AND |
| | DETAILS DON'T PROVIDE THIS INFORMATION. |
| | SEC. 507, SEC. 1101.1 FBC-EXISTING BUILDING. |
| | |
| | 6- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS AS |
| | SHOWN ON PLANS. AND REQUIRED: CLEARLY SPECIFY MULLION |
| | SIZE TO BE USED TO VERIFY COMPLIANCE WITH THE |
| | CALCULATED DESIGN PRESSURES. |
| | FAC 61G20.3001 |
| | |
| | 7-ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |