Plan Review Notes
Plan Review Notes For Permit 20090202
Permit Number 20090202
Review Stop B
Sequence Number 1
Notes
Date Text
2020-10-23 09:13:03PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 VALUE: 12 X 17 ADDITION. 204 SQ. FT. APPLIED VALUE IS
 $9,000.00. ESTIMATED VALUE BASED ON THE ICC BUILDING
 VALUATION TABLES IS $24,982.00.
  
 1. CITY OF WPB CHPT. 1 VALUE
 109.3 BUILDING PERMIT VALUATIONS.
  
 1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK.
 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR,
 MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE
 OF WORK.
 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY
 THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
 BASED ON THE INFORMATION PROVIDED, VALUE CANNOT BE
 DETERMINED AT THIS TIME.
 PLEASE INCREASE THE VALUATION ACCORDINGLY.
  
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL
  
 2. PROPOSED ADDITION HAS AN EXISTING PATIO SLAB.
 DEMONSTRATE HOW YOU WILL COMPLY WITH BELOW GRADE
 MOISTURE BARRIER REQUIREMENTS PER R406.3.2 AND TERMITE
 TREATMENT REQUIREMENTS PER R318.1.
  
 3. THERE IS A STEM WALL DETAIL ON PLAN PAGE S-1. SHOW
 THE LOCATION OF THIS STEM WALL ON PLAN.
  
 4. UNDER FLOOR VENTILATION MAY BE REQUIRED IF STEM WALL
 IS USED PER R408.1
  
 5. PLANS USE BUILDING CODE REFERENCES FOR DESIGN.
 PROVIDE CONSTRUCTION DRAWINGS PER 107.2
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 6. PROVIDE A COMPLETE SET OF CONSTRUCTION DRAWINGS:
 INCLUDE THE FOLLOWING DETAILS:
 6A) FOUNDATION DETAIL
 6B) EXTERIOR WALL DETAIL. PLAN SHOWS WOOD FRAMED WALLS.
 PROVIDE DETAIL FOR CONNECTION OF NEW WALL TO EXISTING.
 NOTE ON PLAN PAGE S-1 STATES DESIGN IS BASED ON
 ENGINEERED UNIT MASONRY. PLEASE CLARIFY.
 6C) PROVIDE ROOF FRAMING PLAN.
 6D) PROVIDE A CONNECTOR SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 7. BEDROOM WINDOW SHALL COMPLY WITH EGRESS REQUIREMENTS
 PER R310.2.
 R311.1MEANS OF EGRESS.
 DWELLINGS SHALL BE PROVIDED WITH A MEANS OF EGRESS IN
 ACCORDANCE WITH THIS SECTION. THE MEANS OF EGRESS SHALL
 PROVIDE A CONTINUOUS AND UNOBSTRUCTED PATH OF VERTICAL
 AND HORIZONTAL EGRESS TRAVEL FROM ALL PORTIONS OF THE
 DWELLING TO THE REQUIRED EGRESS DOOR WITHOUT REQUIRING
 TRAVEL THROUGH A GARAGE. THE REQUIRED EGRESS DOOR SHALL
 OPEN DIRECTLY INTO A PUBLIC WAY OR TO A YARD OR COURT
 THAT OPENS TO A PUBLIC WAY.
  
 EXISTING BUILDING EGRESS WINDOWS
 702.5 EMERGENCY ESCAPE AND RESCUE OPENINGS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  