| Date |
Text |
| 2020-11-03 09:42:34 | |
| | 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY |
| | CLASSIFICATION PER FBC CHAPTER 3. |
| | 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY |
| | WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET |
| | THE INTENT OF THE CODE. |
| | 3) PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE |
| | SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC |
| | ACCESSIBILITY 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | 4) THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET |
| | NEED TO BE SHOWN FROM THE CENTER LINE OF THE WATER |
| | CLOSET SEE FBC ACCESSIBILITY FIGURE 604.5.2 |
| | 5) TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE |
| | SHOWN TO THE CENTER OF THE DISPENSER SEE FBC |
| | ACCESSIBILITY FIGURE 604.7 |
| | 6) THE LOCATION OF THE GRAB BAR ADJACENT TO THE TOILET |
| | SHALL COMPLY WITH FBC-ACCESS. SEC.604.5.1 & FIGURE |
| | 604.5.1. |
| | 7) THE SIDE ELEVATION STILL SHOWS THE GRAB BAR MEASURED |
| | TO THE CENTERLINE OF THE BAR. THE BAR SHALL BEE MEASURE |
| | TO THE TOP OF THE GRIPPING SURFACE. FBS- ACCESS. |
| | 609..4. |
| | 8) SHOW THE REQUIRED CLEAR FLOOR SPACE DIMENSIONS FOR |
| | THE TOILET AND LAVATORY IN THE TOILET ROOM PER |
| | FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1 AND 606..2 |
| | AND SECS.305 & 306. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | CITY OF WEST PALM BEACH |
| | 561-805-6692; [email protected] |
| | |