| Date |
Text |
| 2020-09-16 18:14:33 | 1ST REVIEW FBC-2017 PLUMBING |
| | PERMIT-20081406 |
| | 9/16/2020 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED |
| | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS |
| | TO THE FBC SEC. 105.1. |
| | |
| | 2. SUBMIT A SLAB REPAIR DETAIL FOR REVIEW. SHOW THE |
| | WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE |
| | CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE. |
| | SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM |
| | EMBEDMENT DEPTH INTO THE EXISTING SLAB, AND THE SPACING |
| | OF THE DOWELS ON THE CENTER. THE REPAIR SHALL ALSO |
| | INCLUDE TERMITE TREATMENT OF THE SOIL AND THE REQUIRED |
| | VAPOR BARRIER OVER THE SOIL. A COPY OF THE TERMITE |
| | CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION. |
| | |
| | 3. PLEASE PROVIDE WHAT TYPE OF OCCUPANCY THIS INTERIOR |
| | BUILD-OUT WILL BE AND THE OCCUPANCY LOAD WPB AMENDMENTS |
| | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS. |
| | |
| | 4. THERE IS MEASUREMENT DISCREPANCIES ON THE GRAB BAR |
| | LOCATIONS AND THE TOILET PAPER LOCATION PLEASE REFER TO |
| | FBC ACC 603, FBC ACC 604.5.1 FBC ACC 604.7 |
| | |
| | 5. DOOR CANNOT SWING OUT AND OBSTRUCT LIFESAFETY TRAVEL |
| | PATH TO THE EXIT REAR DOOR FBC ACC 603.2.3 |
| | |
| | 6. THE PLUMBING PLAN SHALL BEAR THE TITLE BLOCK AND |
| | ELECTRONIC SEAL AND SIGNATURE OF THE FL. LICENSED |
| | ARCHITECT OR ENGINEER WHO PREPARED THE DRAWING- SECTION |
| | 107.2.1 WPB, FL. STATUTES 471.025 & 481.221, AND |
| | SECTIONS 61G15-23.005 & 61G1-16.005 FAC. |
| | CONTRACTOR- DRAWN PLANS SHALL BEAR THE TITLE BLOCK, |
| | LICENSE NUMBER, AND SIGNATURE OF THE FL. LICENSED |
| | CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING- |
| | SECTION 107.2.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | ATELYO BELISLE |
| | PLUMBING INSPECTOR / |
| | PLUMBING PLAN REVIEW |
| | AVAILABLE FROM 1:00 PM TO 4:00 PM |
| | [email protected] |
| | 561-805-6695 |
| | |