| Date |
Text |
| 2020-09-10 16:56:02 | 1ST REVIEW FBC-2017 RES. |
| | PERMIT- 20081400 |
| | 9/10/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET P1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR |
| | THE WATER HEATER AND PROVIDE AN EQUIPMENT SCHEDULE ON |
| | THE PLAN INDICATING MAKE, MODEL, GALLON SIZE, AND |
| | EFFICIENCY RATING- SECTION C404.2 FBC EC. |
| | |
| | 2) P1, WATER RISER: SHOW THE WATER LINE CONNECTIONS TO |
| | THE ISLAND SINK, DISHWASHER, REFRIGERATOR ICE MAKER, |
| | AND THE HOSE BIBB- P2903.7 FBC RES. |
| | |
| | 3) P1, WATER RISER: SHOW THE LOCATIONS OF REQUIRED |
| | WATER HAMMER ARRESTORS FOR SUPPLY LINES TO THE |
| | DISHWASHER, WASHING MACHINE AND REFRIGERATOR ICE MAKER- |
| | SECTION P2903.5 FBC RES. |
| | |
| | 4) P1, WATER RISER: SHOW THE REQUIRED BACKFLOW |
| | PREVENTER FOR THE SUPPLY LINE TO THE ICE MAKER- |
| | SECTION- P2902.1 FBC RES. |
| | |
| | 5) P1: PLEASE NOTE THAT A FL. LICENSED PLUMBING |
| | CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR |
| | INSTALLATION OF THE WATER SERVICE BACKFLOW PREVENTER IN |
| | ACCORDANCE WITH SECTION 105.1 WPB AND SEC, 90-33 WPB |
| | CODE OF ORDINANCES. THE DEVICE SHALL BE TESTED AND |
| | CERTIFIED BY THE WPB UTILITIES DEPARTMENT PRIOR TO |
| | FINAL INSPECTION BY THE BUILDING DEPARTMENT. PLEASE |
| | CONTACT THE WPB UTILITIES CENTRAL OPERATIONS DEPT.AT |
| | 561-822-2210 FOR FURTHER INFORMATION. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |