| 2020-10-04 14:53:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20081311 |
| | ADD: 2277 PALM BEACH LAKES BLVD. |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: 281-960-9605 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: SUN. OCT. 04TH/2020 |
| | ACTION: DENIED |
| | |
| | NOTICE: FOR BUILDING REVIEW NO TRANSMITTAL LETTER WAS |
| | SUBMITTED. PLANS DO NOT RELECT A VERSION 2. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) |
| | |
| | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? |
| | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
| | |
| | SECOND REQUEST FOR ALL COMMENTS: |
| | 1) UNDER FLORIDA LICENSING LAWS A LICENSED COMPANY/ |
| | INDIVIDUAL (QUALIFIER) MUST APPLY FOR A PERMIT TO |
| | INSTALL A MANUFACTURED BUILDING. WE COULD NOT SEE WHERE |
| | SATELLITE STRUCTURES HAS ANY FLORIDA LICENSING. |
| | |
| | 2) PLEASE NOTE THE SUBMITTED SURVEY DOES NOT SHOW THIS |
| | PROPERTY IS IN AN AE FLOOD ZONE. PLEASE SUBMIT A |
| | CURRENT SURVEY SHOWING THE LOCATION OF THE AE FLOOD |
| | ZONE AND THE PROPOSED LOCATION OF THE NEW MANUFACTURED |
| | BUILDING. IF THE MANUFACTURED BUILDING IS IN AN AE |
| | FLOOD ZONE, THEN THE BOTTOM OF THE FLOOR FRAMING MUST |
| | BE ABOVE THE BASE FLOOD WITH THE ADDITIONAL 2 FEET |
| | FREEBOARD BY WEST PALM BEACH FLOOD ORDINANCES. |
| | |
| | FLOOD ZONE CERTIFICATES/ SURVEYORS- DEPT. OF |
| | AGRICULTURE |
| | ARTICLE XVII ORDINANCES ARTICLE XVII FLOOD PREVENTION & |
| | CONTROL |
| | FBC BUILDING 1612 AND CITY OF WPB CODE OF SECTION |
| | 94-546. STRUCTURE IS IN AN "A" FLOOD ZONE. A FLOOD |
| | ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE REVIEW |
| | CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE AN |
| | ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION IF PERMIT |
| | APPLICATION AFTER SEPT. 12/2016, |
| | AFTER OCT. 11/ 2017 AN ADDITIONAL ONE FOOT OF FREE |
| | BOARD WILL BE REQUIRED OR (2) FEET ABOVE BASE FLOOD. |
| | AFTER OCT. 11/ 2017 THE BUILDING DEPARTMENT WILL HAVE |
| | ADOPTED THE NEW FLOOD MAPS IN NAVD 88 ELEVATIONS. YOU |
| | CAN GO TO THE WEBSITE: |
| | WWW.NGS.NOAA.GOV/TOOLS/VERTCON/VERTCON.HTML FOR |
| | CONVERSIONS. |
| | |
| | 3) THE SUBMITTED SURVEY SHOWS THE LOCATION OF THE |
| | MANUFACTURED BUILDING AND EXISTING BUILDING BUT DOES |
| | NOT PROVIDE AN ASSUMED PROPERTY LINE BETWEEN THE 2 |
| | STRUCTURES NOR SHOW WALL AND WINDOW RATINGS BECAUSE OF |
| | THE CLOSENESS OF THE 2 STRUCTURES. SEE 2017 FBC-B |
| | SECTIONS: |
| | TABLE 602 FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS |
| | BASED ON FIRE SEPARATION DISTANCE |
| | TABLE 705.8 FIRE SEPARATION DISTANCE AND DEGREE OF |
| | OPENING PROTECTIVES. |
| | |
| | 4) STAIR & RAMP SHEETS 11-19ALL SHOW THEY ARE APPROVED |
| | IN TEXAS, THEY DO NOT SHOW A FLORIDA REGISTERED |
| | ENGINEER. FLORIDA STATUTE 471. |
| | |
| | 5) SHEET 10 THE ACCESSIBLE RAMP SHEET INDICATES THE TOP |
| | LANDING IS 5 FEET 4 INCHES BY 5 FEET 4 INCHES. THE PLAN |
| | IS NOT CLEAR IF THIS IS A OUTSIDE MEASUREMENT OR INSIDE |
| | MEASUREMENT OF THE GUARDRAIL? THE TOP LANDING MUST BE A |
| | CLEAR LANDING OF 60 INCHES BY 60 INCHES CLEAR. 2017 |
| | FBC-ACCESSIBILITY CODE 405.7.4. |
| | |
| | 6) SHEET 10 THERE IS NO DIMENSION FROM THE LATCH SIDE |
| | OF THE DOOR TO THE GUARDRAIL TO THE RIGHT SIDE OF THE |
| | DOOR. WHEN CALIBRATING THE PLAN AND MEASURING THE |
| | DISTANCE FROM THE EDGE OF DOOR TO THE GUARDRAIL THERE |
| | APPEARS TO BE ONLY 18 INCHES. THE 2017 |
| | FBC-ACCESSIBILITY CODE REQUIRES 2-0 FEET MANEUVERING |
| | CLEARANCE SEE FIGURE 404.2.4.1(H). |
| | |
| | 7) SHEET 2 SHOWS THE MANUFACTURES BUILDING FLOOR PLAN |
| | AND NO LAYOUT OF THE STAIRS AND LANDING NOR THE RAMP |
| | AND TOP LANDING. THE SHEET 10 FOR THE RAMP INDICATES |
| | THE RAMP AND TOP LANDING ARE 35 FEET 4 INCHES LONG THE |
| | DISTANCE BETWEEN THE 2 DOORS IS ONLY 31.20 FEET. PLEASE |
| | PROVIDE THE FLOOR PLAN WITH BOTH LANDINGS FOR DOOR AND |
| | RAMP PLUS THE STAIR AND RAMP. 107.2.1.2 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 8) PLEASE PROVIDE HOW LONG THIS UNIT IS INTENDED TO BE |
| | AT THIS SITE, MAY REQUIRE IMPACT FEES. |
| | |
| | 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |