| Date |
Text |
| 2020-09-10 16:36:59 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 20081205 |
| | ADD: 1641 WORTHINGTON RD. SUITE # 410 |
| | CONT: ANDERSON-MOORE CONSTRUCTION CO. |
| | TEL: 561-348-4805 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. SEPT. 10TH/2020 |
| | ACTION: DENIED |
| | |
| | 1) SHEETS ALS1.1 & A1.1.1 BOTH ARE MISSING THE DOOR TO |
| | THE 1 HOUR RATED CORRIDOR MISSING DOOR AND SWING. SHEET |
| | A1.1.1 DOES IDENTIFY THE MISSING DOOR AS DOOR # 121. |
| | SHEET A2.0 THE DOOR SCHEDULE DOES INDICATE THE DOOR TO |
| | BE A 45-MINUTE FIRE RATED DOOR. PLEASE SHOW COMPLIANCE |
| | WITH THE 2017 FBC-B SECTION 1010.1.2.1 DIRECTION OF |
| | SWING. PIVOT OR SIDE HINGED SWINGING DOORS SHALL SWING |
| | IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM |
| | OR AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE. |
| | |
| | 2A) SHEET A-4.03 DETAIL # 1 THE BASE ACCESSIBLE CABINET |
| | FOR BREAK ROOM SINK. THE DETAIL IS MISSING THE |
| | ACCESSIBLE REQUIREMENTS FOR KNEE AND TOE CLEARANCES. |
| | PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY |
| | CODE: |
| | 306.2 TOE CLEARANCES |
| | 306.3 KNEE CLEARANCES. |
| | |
| | 2B) 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY & |
| | DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE |
| | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST |
| | CONTACT. |
| | |
| | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |