| Date |
Text |
| 2020-10-04 14:25:05 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2017 FBC- BUILDING PLAN REVIEW/ UNIVERSITY PREPARATORY |
| | ACADEMY |
| | W. P. B. PERMIT: 20080995 |
| | ADD: 2101 AUSTRALIAN AVE. |
| | CONT: P & T CONSTRUCTION |
| | TEL: 561-324-8050 |
| | E-MAIL: [email protected] |
| | |
| | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: SUN. OCT. 04TH/ 2020 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1: |
| | 1A) THE RESPONSE SHEET INDICATES THE INTERIOR |
| | DEMOLITION SHEET WILL BE INCLUDED IN THE SET OF PLANS |
| | AS INDICATED BY THE PLAN INDEX. NOT IN THE 2ND REVIEW |
| | CYCLE. |
| | 1ST ROUND COMMENTS. THE INDEX OF DRAWINGS INDICATES |
| | THERE IS A DEMO SHEET WHICH IS NOT IN THIS SET OF |
| | PLANS. PART OF THE PLAN REVIEW EXERCISE IS TO SEE WHAT |
| | IS EXISTING AND WHAT IS TO BE DEMOLISHED. 107.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED. THERE IS A DISCREPANCY |
| | IN THE SUBMITTED PLAN SET AND INDEX. |
| | |
| | 1B) 2ND ROUND OF COMMENTS, NOT ADDRESSED. THERE IS NO |
| | EXISTING BUILDING CODE FOR STATE LICENSED FACILITIES |
| | (CHARTER SCHOOLS, PRIVATE SCHOOLS), SEE CHAPTER 4, |
| | SPECIAL OCCUPANCIES, OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | SECTION 468.1 IS FOR FLORIDA?S PUBLIC AND PRIVATE |
| | SCHOOLS, COLLEGES AND UNIVERSITIES. THERE IS NO |
| | EXISTING BUILDING CODE TO GO BY UNDER SPECIAL |
| | OCCUPANCIES FOUND IN CHAPTER 4. IN THE 2017FBC-B |
| | SECTION 468.1 SCOPING DEALS WITH FLORIDA?S PUBLIC, |
| | PRIVATE SCHOOLS, COLLEGES AND UNIVERSITIES. |
| | |
| | 1ST ROUND OF COMMENTS. UNDER THE HEADING OF BUILDING |
| | BASICS THE PLANS STATE ALTERATION LEVEL L11- |
| | PRESCRIPTIVE COMPLIANCE METHOD (301.1.1). I?M NOT SURE |
| | WHAT METHOD IS BEING CONVEYED? |
| | PLEASE NOTE THIS IS A PARTIAL CHANGE OF OCCUPANCY FROM |
| | AN A-4 INDOOR SPORTING EVENTS WITH SPECTATOR SEATING TO |
| | E, EDUCATIONAL. PLEASE REVIEW THE SCOPING REQUIREMENTS |
| | IN THE 2017 EXISTING BUILDING CODE 101.2 THE EXCEPTION. |
| | PLEASE BE AWARE OF THE 2017 FBC-EXISTING BUILDING CODE |
| | SCOPING REQUIREMENTS AND THE EXCEPTION FOUND UNDER |
| | SECTION 101.2. EXCEPTION: 2. |
| | EXCEPTION 2 DOES NOT ALLOW THE USE OF THE EXISTING |
| | BUILDING CODE; IT REFERS YOU BACK TO THE BUILDING CODE |
| | FOR NEW CONSTRUCTION. FOR THE PURPOSE OF PUBLIC |
| | EDUCATIONAL FACILITIES AND STATE LICENSED FACILITIES |
| | (CHARTER SCHOOLS, PRIVATE SCHOOLS), SEE CHAPTER 4, |
| | SPECIAL OCCUPANCIES, OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | SECTION 468.1 IS FOR FLORIDA?S PUBLIC AND PRIVATE |
| | SCHOOLS, COLLEGES AND UNIVERSITIES. THERE IS NO |
| | EXISTING BUILDING CODE TO GO BY UNDER SPECIAL |
| | OCCUPANCIES FOUND IN CHAPTER 4. IN THE 2017FBC-B |
| | SECTION 468.1 SCOPING DEALS WITH FLORIDA?S PUBLIC, |
| | PRIVATE SCHOOLS, COLLEGES AND UNIVERSITIES. |
| | |
| | 1C-D) THE RESPONSE INDICATES TO SEE THE TABLE 2902.1 ON |
| | SHEET A-3 INDICATES THE BREAK DOWN OF TOILETS BUT THERE |
| | IS ONLY ONE RESTROOM DESIGNATED FOR TEACHERS THAT IS IN |
| | THE TEACHER PLANNING ROOM. THERE ARE 26 CLASSROOMS, 26 |
| | TEACHERS + 8 KITCHEN STAFF AND PROBABLY AT LEAST 8 |
| | ADMINISTRATIVE STAFF (NOT INCLUDED IN TABLE 2902.1) |
| | BRINGING THE ADULT STAFF UP TO 42 OCCUPANTS REQUIRING 2 |
| | ADULT TOILETS. 2017 FBC-B SECTION 468.5.2 TEACHERS |
| | TOILETS |
| | 1ST ROUND OF COMMENTS. THERE IS NOT ENOUGH INFORMATION |
| | ON THE PLAN TO DETERMINE CODE COMPLIANCE FOR CODE |
| | COMPLIANCE FOR THE REQUIRED NUMBER OF FIXTURES REQUIRED |
| | UNDER THE 2017 FBC-B TABLE 2902.1 FOR EDUCATION. |
| | |
| | 1D) PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION |
| | 468.5.2 TEACHERS TOILETS. FACILITIES AND STAFF TOILETS |
| | SHALL BE SEPARATE FROM STUDENT TOILETS. |
| | |
| | 1E-H) COMPLIED. |
| | |
| | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| | 19 |
| | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| | 561-718-9724. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |