Plan Review Notes
Plan Review Notes For Permit 20080231
Permit Number 20080231
Review Stop P
Sequence Number 2
Notes
Date Text
2020-10-23 15:17:192ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20080231
 10/23/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) BASED ON THE RESUBMITTED BETHROOM PLANS AND RESEARCH
 OF THE PLANS UNDER THE ORIGINAL BUILDING PERMIT-
 99061677, IT APPEARS THE BATHROOM WAS ORIONGALLY
 DESIGNED AS A SPECIFICATION A TYPE BATHROOM BECAUSE OF
 THE LOCATION OF THE WATER CLOSET ADJACENT TO THE
 BATHTUB- SEE PAGE 7.36 OF THE FAIR HOUSING ACT MANUAL.
 UNDER SPECIFCATION A ONLY A FORWARD 30 X 48 IN.
 WHEELCHAIR APPROACH CAN BE ACCOMPLISHED WHICH WAS
 COMPLIANT FOR THE BATHTUB, HOWEVER THE NEW SHOWER WILL
 REQUIRE A 30 X 48 IN. PARALLEL APPROACH WHICH CANNOT BE
 ACCOMPLISHED BECAUSE OF THE LOCATION OF THE TOILET- SEE
 PAGES 7.56- 7.59.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 FAIRHOUSING COMPLIANCES AND GUIDELINES FOR THE
 BATHTUB/SHOWER CONVERSION ALTERATION, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 SO REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 2) 2ND REQUEST FOR THE SHOWER PAN DETAIL- SECTION 417.5
 FBC P.
  
 3) 2ND REQUEST TO SUBMIT A PLUMBING SUB-PERMIT
 APPLICATION- SECTION 105.1 WPB.
  
 4) THE SIGNATURE OF THE FL. LICENSED PLUMBING
 CONTRACTOR OR QUALIFIER SHALL BE ON THE SUBMITTED PLANS
 IN ACCORDANCE WITH SECTION 107.2.1 WPB, AND FLORIDA
 STATUTES 471.003(2)(H) & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  