| 2020-10-02 15:57:29 | PLAN REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC SIXTH EDITION (2017) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THIS ITEM CAN NOT BE DEFERRED. THE DRAINAGE PLAN |
| | THAT WAS SUBMITTED IS NOT ACCEPTABLE. SUBMIT A DRAINAGE |
| | PLAN WITH ELEVATIONS SPECIFIED TO SHOW THAT THE STORM |
| | WATER WILL BE RETAINED ON THE PROPERTY AND NOT DIVERTED |
| | TO NEIGHBORING PROPERTIES UNTIL IT IS ROUTED TO AN |
| | APPROVED STORM SEWER OR OTHER APPROVED COLLECTION |
| | POINT. SUBMIT A LOT DRAINAGE PLAN TO SHOW COMPLIANCE |
| | WITH CITY AMENDMENTS FBC 107.2.5 AND R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN |
| | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE |
| | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE |
| | FIRST 10 FEET (3048 MM). |
| | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| | PERCENT AWAY FROM THE BUILDING. |
| | |
| | 2) THIS ITEM CAN BE DEFERRED. SUBMIT SIGNED AND SEALED |
| | TRUSS LAYOUT PLAN AND TRUSS DRAWINGS THAT HAVE BEEN |
| | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. |
| | FBC-R802.10 |
| | |
| | |
| | |
| | |
| | |
| | |