Plan Review Notes
Plan Review Notes For Permit 20080092
Permit Number 20080092
Review Stop P
Sequence Number 1
Notes
Date Text
2020-08-17 14:50:371ST REVIEW FBC-2017 RES.
 PERMIT- 20080092
 8/17/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: THE NEW RISER DIAGRAM DOES NOT INCLUDE THE
 NEW SANITARY DRAIN AND VENT FOR THE NEW STACKABLE
 WASHER/DRYER- SECTION 107.3.5.3 WPB.
  
 2) P1: SHOW THE LOCATION OF THE NEW SHUT-OFF VALVES FOR
 THE NEW W/D TO VERIFY THEY WILL BE ACCESSIBLE- SECTION
 P2903.9.3 FBC RES.
  
 3) P1: PROVIDE THE DIMENSIONS OF THE NEW SHOWER-
 SECTION P2708.1, AND A CONSTRUCTION DETAIL FOR THE NEW
 RECESSED SHOWER AND DRAIN & SECTION P2709.2.
  
 4) P1: PLACE NOTES ON THE PLAN TO VERIFY THE O.F.C.I.
 SHOWER VALVE AND TUB FAUCET WILL BE IN COMPLIANCE WITH
 SECTIONS P2708.4 AND P2713.3:
 P2708.4: THE SHOWER VALVE SHALL BE EQUIPPED WITH
 CONTROL VALVES OF THE PRESSURE-BALANCE,
 THERMOSTATIC-MIXING OR COMBINATION
 PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A
 HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME
 A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET
 TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN 120
 DEGREES F
 P2713.3: HOT WATER SUPPLIED TO BATHTUBS AND WHIRLPOOL
 BATHTUBS SHALL BE LIMITED TO A TEMPERATURE OF NOT
 GREATER THAN 120 DEGREES F BY A WATER TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA
 B125.3.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  