| 2020-08-19 14:43:55 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 680.26 EQUIPOTENTIAL BONDING (A) PERFORMANCE. THE | | | EQUIPOTENTIAL BONDING REQUIRED BY THIS SECTION SHALL BE | | | INSTALLED TO REDUCE VOLTAGE GRADIENTS IN THE POOL AREA. | | | (B) BONDED PARTS. THE PARTS SPECIFIED IN 680.26(B)(1) | | | THROUGH (B)(7) SHALL BE BONDED TOGETHER USING SOLID | | | COPPER CONDUCTORS, INSULATED COVERED, OR BARE, NOT | | | SMALLER THAN 8 AWG OR WITH RIGID METAL CONDUIT OF BRASS | | | OR OTHER IDENTIFIED CORROSI ON-RESISTANT METAL. | | | | | | POOL LIGHTS LOOK AS IF THEY WERE REPLACED, NEED TO SHOW | | | WHAT TYPE OF FIXTURES ARE BEING USED. | | | |
|