Plan Review Notes
Plan Review Notes For Permit 20071356
Permit Number 20071356
Review Stop B
Sequence Number 1
Notes
Date Text
2020-08-03 15:48:51WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20071356
 ADD: 215 PERSHING WAY
 CONT: PALM BEACH ALUMINUM
 TEL: 561-844-8285
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. AUGUST 03/2020
 ACTION: DENIED
  
 1) THE SUBMITTED PARTIAL FLOOR PLAN SUBMITTED BY PALM
 BEACH ALUMINUM HAS 5 IMPACT WINDOWS BEING INSTALLED AND
 ONE EXTERIOR SLIDING GLASS DOOR TO THE EXTERIOR OF THE
 BUILDING THAT IS LISTED AS NON-IMPACT GLAZING. IT IS
 UNUSUAL TO SEE PLANS COME IN WITH NON-IMPACT GLAZING
 WITHOUT A NOTE THERE ARE EXISTING STORM SHUTTERS. IF
 THIS OPENING IS IN THE SUN ROOM THIS MAY HELP. I LOOKED
 INTO OUR ELECTRONIC/ DIGITAL RECORD KEEPING (FILE NET)
 TO SEE IF THERE EVER WERE ANY STORM SHUTTER PERMITS AND
 FOUND NONE. I DID FIND A RECORD FOR A GLASS ROOM
 ENCLOSURE PERMIT 94015242 UNDER THE 1991 SBC WIND SPEED
 110 MPH (FASTEST MILE). WHAT THE PLANS DO STATE PAGE 6
 OF 7 THAT 5/16 INCH LAMINATED GLAZING WAS USED IN THE
 INSTALLATION. THIS KNOWLEDGE NEEDS TO BE ADDED TO THE
 SUBMITTED PLAN TO SHOW WHY NON-IMPACT GLAZING CAN BE
 INSTALLED AND IF THE SUN ROOM IS EVER REMOVED THEN
 STORM SHUTTERS WOULD BE REQUIRED FOR THIS OPENING.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  