| Date |
Text |
| 2021-04-12 10:59:17 | FAILED |
| | |
| | FASCIA IDENTITY SIGN A (SIGN COMPLIES WITH ZONING |
| | REVIEW AS SHOWN) |
| | |
| | 1) CITYPLACE RETAIL HAS GRANTED A WAIVER I FOR THE |
| | FASCIA SIGN AT THIS LOCATION. THE ROTUNDA DIMENSION IS |
| | USED AS THE FACADE OF THE BUILDING FOR THE PURPOSES OF |
| | SIGN FRONTAGE. |
| | |
| | PERMITTED SIGN ON ROTUNDA: 59.75 SF |
| | PROPOSED SIGN ON ROTUNDA: 24.44 SF |
| | |
| | 2) THE LIGHTING REQUIRES A SEPARATE PERMIT, WITH PLANS. |
| | |
| | FASCIA IDENTITY SIGN H (SIGN DOES NOT COMPLY WITH |
| | ZONING REVIEW AS SHOWN) |
| | |
| | 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT THE LETTER CHANNELS FOR INTERNALLY ILLUMINATED |
| | FASCIA IDENTITY SIGNS BE STUD MOUNTED A MAXIMUM OF ONE |
| | (1) INCH FROM THE FACE OF THE WALL. THE SECTION DRAWING |
| | SHOWS THE ACRYLIC EDGE-LIT AT THE BACK OF THE CHANNEL |
| | LETTER ONE INCH FROM THE WALL, WHILE THE SPECIFICATIONS |
| | LIST THE LETTERS AT ONE AND ONE-HALF INCH FROM THE |
| | WALL. EITHER THE EDGE-LIT IS PART OF THE CHANNEL LETTER |
| | AND THE SIGN COMPLIES OR THE SIGN NEEDS TO BE CLOSER TO |
| | THE WALL. |
| | |
| | 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA DO NOT |
| | PERMIT THE USE OF ACRYLIC EXCEPT FOR PUSH THROUGH |
| | APPLICATIONS UNLESS SPECIFICALLY GRANTED A WAIVER I |
| | APPROVAL BY CITYPLACE RETAIL, LLC, FOR THE USE OF |
| | ALTERNATIVE MATERIALS THAN THOSE SPECIFIED IN THE |
| | MASTER SIGN PLAN. PLEASE PROVIDE THE WAIVER I APPROVAL |
| | LETTER WITH THE RESUBMITTAL. |
| | |
| | 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT ALL CONDUIT, CROSSOVERS, WIRING, BALLAST BOXES, |
| | TRANSFORMERS, ETC. NECESSARY FOR THE SIGN'S ELECTRICAL |
| | CONNECTION TO BE CONCEALED AND NOT VISIBLE TO THE |
| | PUBLIC. THE DRAWING LABELED 2021-02-15 TRUE FOOD |
| | KITCHEN (SIGN H) 16.PDF APPEARS TO SHOW THE POWER |
| | SUPPLY BEHIND A WALL WITH THE LOW VOLTAGE SECONDARY |
| | POWER FEED THROUGH THE WALL AT A STUD MOUNT TO THE |
| | LETTER. 2021-02-15 TRUE FOOD KITCHEN (SIGN H) 17.PDF |
| | SHOWS A TRANSFORMER BOX LOCATED BEHIND THE BUILDING |
| | WALL, BUT NO CONNECTION TO THE LETTERS. |
| | |
| | A. THE PLANS MUST CLEARLY VERIFY THAT ALL ELECTRICAL |
| | COMPONENTS (TO INCLUDE A BELL BOX) ARE LOCATED BEHIND |
| | THE BUILDING WALL AND NOT VISIBLE FROM BELOW (THE |
| | ARCADE WALKWAY). |
| | B. THE PLANS MUST CLEARLY SHOW HOW THE POWER GETS FROM |
| | BEHIND THE WALL TO THE INDIVIDUAL LETTERS WITHOUT BEING |
| | VISIBLE ON THE EXTERIOR OF THE WALL. NOTE: YOU MAY NOT |
| | RUN CONDUIT ON THE EXTERIOR OF THE WALL. |
| | |
| | 6) THIS SIGN IS MOUNTED ON THE WEST FACADE OF THE |
| | BUILDING. THE FRONTAGE DOES NOT INCLUDE ANY ROTUNDA |
| | AREA AS IT IS CALCULATED WITH SIGN A. |
| | |
| | PERMITTED SIGN ON WEST FACADE: 70 SF |
| | PROPOSED SIGN ON WEST FACADE: 31 SF |
| | |
| | PERMITTED: 59.9 SF |
| | PROPOSED: 24.43 SF |
| | |